MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000001109

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2017

Prediction of Orthokeratology Lens Decentration with Corneal Elevation.

Chen Zhi, Xue Feng, Zhou Jiaqi, Qu Xiaomei, Zhou Xingtao, Shanghai Orthokeratology and Study (SOS) Group

СтатьяПеревод пока не подготовлен

Аннотация

SIGNIFICANCE: Lens decentration is common and unavoidable to some extent during ortho-k treatment. By using a simplified method, we are able to predict the magnitude and direction of ortho-k lens decentration, which provides useful insights in screening for ideal ortho-k candidates and to make a quick decision when decentration happens.

PURPOSE: The aim of this study was to investigate the influence of corneal elevation asymmetry on ortho-k lens decentration.

METHODS

Thirty-six eyes of 36 subjects were fitted with four-curve reverse geometry ortho-k contact lenses. Corneal topography was collected before and 1 month after ortho-k lens wear. The difference in corneal elevation at the 8-mm chord of the respective two principal meridians of corneal astigmatism was calculated. Vector analyses were performed on these differences to calculate the magnitude and direction of a vector (corneal asymmetry vector). The relationship between the angle and magnitude of corneal asymmetry vector and lens decentration was analyzed.

RESULTS

Baseline refractive sphere and cylinder for the 36 tested eyes were -2.84 ± 1.04 diopters (D) (range, -4.75 to -1.00 D) and -0.21 ± 0.28 D (range, -1.00 to 0 D), respectively. The mean magnitude of lens decentration was 0.72 ± 0.26 mm (0 to 1.34 mm). For overall displacement, inferotemporal decentration was the most common as observed in 24 eyes (67%). The mean angle of the corneal asymmetry vector (202 ± 39 degrees) was significantly correlated to the mean angle of lens decentration (200 ± 39 degrees) (r = 0.76, P < .001). The magnitude of corneal asymmetry vector significantly contributed to the magnitude of lens decentration (standardized β = 0.448, P = .002) whereas the other tested variables did not affect lens decentration (all P > .05).

CONCLUSIONS

Lens decentration is a common phenomenon in ortho-k that mostly happens toward the inferotemporal quadrant of the cornea. The magnitude and direction of lens decentration are predetermined by paracentral corneal asymmetry.

Для цитирования: Chen Zhi, Xue Feng, Zhou Jiaqi, Qu Xiaomei, Zhou Xingtao, Shanghai Orthokeratology and Study (SOS) Group. Prediction of Orthokeratology Lens Decentration with Corneal Elevation.. Optometry and vision science : official publication of the American Academy of Optometry. 2017. DOI: 10.1097/opx.0000000000001109.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.