MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000001290

Медицинская библиотека · Cornea · 2017

Correlation of Corneal Biomechanical Stiffness With Refractive Error and Ocular Biometry in a Pediatric Population.

Matalia Jyoti, Francis Mathew, Gogri Pooja, Panmand Pratibha, Matalia Himanshu, Sinha Roy Abhijit

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the correlation between corneal biomechanical stiffness and refractive error (RE) in the pediatric population.

METHODS

A total of 733 pediatric eyes were included in the study retrospectively. All eyes underwent corneal tomography (Pentacam), RE assessment, and air-puff deformation (Corvis-ST). Waveform analyses of deformation provided corneal stiffness (CS) and extraocular tissue stiffness (EOS). Eyes were subgrouped into emmetropia [manifest refraction spherical equivalent (MRSE) ∼ 0 D], hyperopia (MRSE > 0 D), myopia I (MRSE between 0 D and -3 D), myopia II (MRSE between -3 D and -6 D), and myopia III (MRSE greater than -6 D) for multivariate analyses. Ocular biometry variables [age, intraocular pressure (IOP), central corneal thickness (CCT), corneal astigmatism, anterior chamber depth, and RE] were used as covariates. The apparent elastic modulus (E) was defined as the ratio of CS and CCT.

RESULTS

All groups had similar age, CCT, and IOP (P > 0.05). CS was the only parameter to differ between all the grades of myopia (P < 0.0001). CS was lower by 3.72%, 6.84%, and 10.68% in myopia I, II, and III eyes, respectively, relative to emmetropic eyes. EOS increased by 11.15%, 22.60%, and 28.5%, respectively. Multivariate regression revealed age, IOP, CCT, corneal astigmatism, anterior chamber depth, and RE as significant predictors of CS, with a high coefficient of regression (R = 0.66). Corneal E negatively correlated with the grade of myopia.

CONCLUSIONS

CS and EOS correlated negatively and positively with the grade of myopia, respectively. Ocular biometry variables were significant predictors of both CS and EOS. The decrease in CS was attributed to that in elastic modulus.

Для цитирования: Matalia Jyoti, Francis Mathew, Gogri Pooja, Panmand Pratibha, Matalia Himanshu, Sinha Roy Abhijit. Correlation of Corneal Biomechanical Stiffness With Refractive Error and Ocular Biometry in a Pediatric Population.. Cornea. 2017. DOI: 10.1097/ico.0000000000001290.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.