MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0886-3350(13)80485-3

Медицинская библиотека · Journal of cataract and refractive surgery · 1995

Effects of flurbiprofen and indomethacin on acute cystoid macular edema after cataract surgery: functional vision and contrast sensitivity.

Ginsburg A P, Cheetham J K, DeGryse R E, Abelson M

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

We examined the effect of acute cystoid macular edema (CME) on contrast sensitivity. Eyedrops were instilled into the surgically treated eye f1p4 times daily for two days preoperatively and for three months postoperatively. Angiographic and clinical CME were measured, as were contrast sensitivity and Snellen acuity. Jaeger visual acuity equivalents were calculated and digital imaging techniques used to simulate visual function. We found that angiographic CME reduces functional vision as measured by contrast sensitivity and visual acuity over a large range of sizes. In patients treated with the flurbiprofen vehicle, those without CME had higher mean contrast sensitivity scores than those with CME; this increased over time. Those treated with flurbiprofen and indomethacin had slightly higher contrast sensitivity scores than vehicle-treated patients; this also increased over time, most notably in the higher spatial frequencies. Flurbiprofen treatment improved contrast sensitivity in patients with and without CME significantly at 12 cycles per degree. Flurbiprofen-treated patients with CME in general had higher contrast sensitivity scores than vehicle-treated patients. In this population of patients having cataract surgery, treatment with flurbiprofen or indomethacin reduced the loss of functional vision associated with CME.

Для цитирования: Ginsburg A P, Cheetham J K, DeGryse R E, Abelson M. Effects of flurbiprofen and indomethacin on acute cystoid macular edema after cataract surgery: functional vision and contrast sensitivity.. Journal of cataract and refractive surgery. 1995. DOI: 10.1016/s0886-3350(13)80485-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.