MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0003489400109s1209

Медицинская библиотека · The Annals of otology, rhinology & laryngology. Supplement · 2000

Shaw scalpel in revision cochlear implant surgery.

Roland J T, Fishman A J, Waltzman S B, Cohen N L

СтатьяПеревод пока не подготовлен

Аннотация

The use of traditional electrocautery is prohibited in revision or replacement cochlear implant surgery because of the concern for end organ tissue damage. Additionally, electrical current spread to the malfunctioning device could interfere with an accurate cause-of-failure analysis. Clinical reports have confirmed the utility of the Shaw scalpel for dermatologic, ophthalmic, and head and neck surgery. The Shaw scalpel is a thermally activated cutting blade that provides a bloodless field through immediate capillary and small vessel hemostasis. Avoidance of wound and flap complications is of primary concern in cochlear implant surgery. The long-term wound healing compared favorably to that of other surgical cutting instruments in several experimental reports. We have routinely used the Shaw scalpel in revision cochlear implant surgery and in primary surgery whenever electrocautery was contraindicated. We have retrospectively evaluated 22 cases in which the Shaw scalpel was used for cochlear implant revision and primary surgery. The chart review included patient demographics, the indication for surgery, the contraindication for electrocautery, intraoperative surgical notes, the wound healing evaluation, the evaluation for alopecia, and postoperative speech understanding. No significant complications occurred intraoperatively, and the long-term wound healing results were no different from those obtained with conventional surgical techniques. The explanted devices were undamaged, and valuable diagnostic information could be obtained. All patients performed at or better than their preoperative levels on speech recognition testing. Our results indicate that the Shaw scalpel is a relatively safe, easy-to-use, and effective instrument.

Для цитирования: Roland J T, Fishman A J, Waltzman S B, Cohen N L. Shaw scalpel in revision cochlear implant surgery.. The Annals of otology, rhinology & laryngology. Supplement. 2000. DOI: 10.1177/0003489400109s1209.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.