BACKGROUND

Pulse arrival time (PAT) is commonly used to estimate blood pressure response. We hypothesised that PAT response to obstructive respiratory events would be associated with increased cardiovascular risk in people with obstructive sleep apnoea.

METHODS

PAT, defined as the time interval between electrocardiography R wave and pulse arrival by photoplethysmography, was measured in the Multi-Ethnic Study of Atherosclerosis Sleep study participants. The PAT response to apnoeas/hypopnoeas was defined as the area under the PAT waveform following respiratory events. Cardiovascular outcomes included markers of subclinical cardiovascular disease (CVD): left ventricular mass, carotid plaque burden score and coronary artery calcification (CAC) (cross-sectional) and incident composite CVD events (prospective). Multivariable logistic and Cox proportional hazard regressions were performed.

RESULTS

A total of 1407 participants (mean age 68.4 years, female 47.5%) were included. Higher PAT response (per 1 SD increase) was associated with higher left ventricular mass (5.7 g/m2 higher in fourth vs first quartile, p<0.007), higher carotid plaque burden score (0.37 higher in fourth vs first quartile, p=0.02) and trended to greater odds of CAC (1.44, 95% CI 0.98 to 2.15, p=0.06). A total of 65 incident CVD events were observed over the mean of 4.1 (2.6) years follow-up period. Higher PAT response was associated with increased future CVD events (HR: 1.20, 95% CI 1.02 to 1.42, p=0.03).

CONCLUSION

PAT is independently associated with markers of subclinical CVD and incident CVD events. Respiratory-related PAT response is a novel and promising polysomnography metric with cardiovascular implications.

Для цитирования: Kwon Younghoon, Wiles Christopher, Parker B Eugene, Clark Brian R, Sohn Min-Woong, Mariani Sara, Hahn Jin-Oh, Jacobs David R, Stein James H, Lima Joao, Kapur Vishesh, Wellman Andrew, Redline Susan, Azarbarzin Ali. Pulse arrival time, a novel sleep cardiovascular marker: the multi-ethnic study of atherosclerosis.. Thorax. 2021. DOI: 10.1136/thoraxjnl-2020-216399.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.