DOI 10.1590/0004-282x-anp-2020-0193
Determining the utility of minimum F-wave latency alterations in the electrodiagnosis of ulnar neuropathy at the elbow.
Аннотация
BACKGROUND
Ulnar neuropathy at the elbow (UNE) is the second most common entrapment neuropathy. There is little information about the application of F-wave studies for evaluation of UNE.
OBJECTIVE
The aim of this study was to evaluate the diagnostic value of minimum F-wave (F-min) latency alterations by comparing this with nerve conduction analyses in UNE-suspected patients.
METHODS
Ninety-four UNE-suspected patients were admitted to this study. Sensory and motor nerve conduction and F-wave analyses on the median and ulnar nerves were performed on both upper extremities.
RESULTS
A total of 188 upper extremities of 94 patients were examined. Their mean age was 41.4±12.9 years, and 69 patients were female (73.4%). The mean ulnar-nerve across-elbow motor conduction velocity (MCV) in the affected arms was significantly slower than the velocity in healthy arms. The mean ulnar-nerve F-min latencies were significantly longer in the affected arms. Fifty-one patients were electrophysiologically diagnosed as presenting UNE (54.2%). Significantly slower mean ulnar-nerve across-elbow MCV, longer mean ulnar-nerve F-min latency and longer distal onset latency were detected in UNE-positive arms. Lastly, patients who were symptomatic but had normal nerve conduction were evaluated separately. Only the mean ulnar F-min latency was significantly longer in this group, compared with the healthy arms.
CONCLUSION
Our study confirmed the utility of F-min latency measurements in the electrodiagnosis of UNE. F-wave latency differences can help in making an early diagnosis to provide better treatment options.