MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archneurol.2009.265

Медицинская библиотека · Archives of neurology · 2009

Optical coherence tomography in clinically isolated syndrome: no evidence of subclinical retinal axonal loss.

Outteryck Olivier, Zephir Hélène, Defoort Sabine, Bouyon Marie, Debruyne Philippe, Bouacha Ikram, Ferriby Didier, Lacour Arnaud, Labalette Pierre, de Seze Jerome, Vermersch Patrick

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Optical coherence tomography has emerged as a new tool for quantifying axonal loss in multiple sclerosis (MS). A reduction in retinal nerve fiber layer (RNFL) thickness is correlated with Expanded Disability Status Scale score and brain atrophy.

OBJECTIVE

To investigate RNFL and macular volume measurements using optical coherence tomography in the clinically isolated syndrome population.

DESIGN

Prospective case series. Settings Neurologic clinics at the university hospitals of Lille and Strasbourg (France).

PARTICIPANTS

Fifty-six consecutive patients with clinically isolated syndrome (18 with optic neuritis and 38 without optic neuritis) and 32 control subjects.

MAIN OUTCOME MEASURES: Macular volume and RNFL thickness.

RESULTS

Mean (SD) overall RNFL thickness (98.98 [10.26] microm) and macular volume (6.86 [0.32] microm(3)) in the clinically isolated syndrome population were not significantly different compared with the controls (98.71 [9.08] mum and 6.92 [0.38] microm(3), respectively). No link was noted between atrophy of the RNFL or macula and conversion to MS at 6 months.

CONCLUSIONS

Optical coherence tomography does not reveal retinal axonal loss at the earliest clinical stage of MS and does not predict conversion to MS at 6 months.

Для цитирования: Outteryck Olivier, Zephir Hélène, Defoort Sabine, Bouyon Marie, Debruyne Philippe, Bouacha Ikram, Ferriby Didier, Lacour Arnaud, Labalette Pierre, de Seze Jerome, Vermersch Patrick. Optical coherence tomography in clinically isolated syndrome: no evidence of subclinical retinal axonal loss.. Archives of neurology. 2009. DOI: 10.1001/archneurol.2009.265.