Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
Evaluation of 9-Minute Dual-Energy Peak Time-Reduced 360° CZT Total-Body [177Lu]Lu-PSMA SPECT/CT Imaging with Comparisons to [68Ga]Ga-PSMA PET.
СтатьяСравнительное исследованиеОценочное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Boursier Caroline, Heyer Sébastien, Zouaoui Abdelaali, Roth Nathaniel, Blum Raphael, Claudin Marine, Olivier Pierre, Marie Pierre-Yves, Verger Antoine, Imbert Laetitia
Аннотация
Eighteen-minute 360° cadmium zinc telluride (CZT) total-body 177Lu-labeled SPECT acquisitions on the single 113-keV 177Lu photopeak (SP-18) have been reported to be suitable for monitoring [177Lu]Lu-PSMA therapy. This study evaluated dual-energy 113- and 208-keV acquisitions with a more than 2-fold increase in acquired counts, allowing acquisition time to be reduced to 9 min (DP-9). Methods: In 20 patients with prostate cancer, 360° CZT total-body 177Lu-labeled SPECT acquisitions performed after the first [177Lu]Lu-PSMA therapeutic injection were reconstructed as SP-18, DP-9, and dual-energy 18-min reconstructions (DP-18), all from the same list-mode dataset, and tumor volume and SUVmean were compared. A standard pretherapy [68Ga]Ga-PSMA PET was also used as an external imaging reference. Results: DP-9 yielded tumor volume and SUVmean that were comparable to those of DP-18. Compared with SP-18, DP-9 produced lower tumor volumes (median percentage difference, -15% [interquartile range, -25% to -12%]) with similar SUVmean Compared with PET, both SP-18 and DP-9 showed higher SUVmean (+14% [+7% to + 36%] and +19% [-3% to +38%], respectively), likely reflecting the longer injection-to-imaging delay for SPECT, and higher tumor volumes (+68% [+5% to + 122%] and +47% [-15% to +95%], respectively), consistent with the lower spatial resolution of SPECT. Phantom results were similar for SPECT reconstructions, with PET showing better recovery coefficients for SUV and volume. Conclusion: Dual-energy 360° CZT total-body [177Lu]Lu-PSMA SPECT/CT enables 9-min acquisitions while providing tumor volume and SUVmean measurements comparable to those of the previously validated 18-min single-energy protocol. Tumor volumes are lower than those with SP-18 but are closer to PET-derived values. Differences between SPECT and PET mainly reflect the injection-to-imaging time for SUVmean and the spatial resolution for tumor volume.
Предметные рубрики MeSH
HumansMaleLutetiumGallium RadioisotopesZincTelluriumOrganometallic CompoundsCadmiumGallium IsotopesTime FactorsRadioisotopesAgedProstatic NeoplasmsEdetic AcidOligopeptidesPositron Emission Tomography Computed TomographyMiddle AgedWhole Body ImagingSingle Photon Emission Computed Tomography Computed TomographyAged, 80 and overProstate-Specific Antigen