An ion treatment planning framework for inclusion of nanodosimetric ionization detail through cluster dose.

Facchiano Simona, Ortiz Ramon, Cristoforetti Remo, D-Kondo Naoki, Jäkel Oliver, Faddegon Bruce, Wahl Niklas

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Nanodosimetry relates the cumulative or statistical moments of Ionization Detail (ID) with biological endpoints of relevance to cancer radiotherapy using charged particles. This association suggests to develop an additional physics-detailed layer of modeling that may complement biological modeling and treatment planning. The recently introduced cluster dose g ( I p ) may serve as a purely physical quantity bridging the Ionization Parameter ( I p ) to the macroscopic treatment planning scale.

PURPOSE: In this work, we developed a framework to enable flexible and direct cluster dose optimization using a pencil-beam algorithm, which we validated with condensed history Monte Carlo (MC) simulations.

METHODS

Cluster dose combines the contributions to I p from all particles within a macroscopic volume. Our framework, implemented in the open source planning toolkit matRad, utilizes the particle and energy-dependent I p values from an ID database precomputed from MC track strucure (MCTS) simulations. First, we create pencil-beam (PB) kernels, including fluence spectra, from condensed history MC simulations. For a water box phantom and a representative prostate patient, we create treatment plans optimized on dose and cluster dose F 5 coverage and homogeneity for protons, helium and carbon ions. Plans were validated with Geant4/TOPAS MC.

RESULTS

Our framework provided accurate, practical cluster dose calculation and planning. PB algorithms achieve typical accuracy for cluster dose calculation comparable to dose calculation. Recalculation with TOPAS on the box phantom yielded 3D gamma passing rates (GPRs) greater than 97 % . For the prostate patient, GPRs exceeded 98 % . Both used the 3 % / 3 m m criterion with a threshold of 10 % of the maximum dose. Using cluster dose F 5 optimization, homogeneous cluster dose target coverage was achieved in all plans. A constant cluster dose prescription across all ion species shows the expected decrease in required absorbed dose for heavier ions.

CONCLUSIONS

We demonstrate that fast, direct cluster dose calculation and optimization is feasible using MC validated planning with PB algorithms. Cluster dose prescription and optimization results in the expected cluster dose coverage and physical dose levels depending on the respective primary ion.

Для цитирования: Facchiano Simona, Ortiz Ramon, Cristoforetti Remo, D-Kondo Naoki, Jäkel Oliver, Faddegon Bruce, Wahl Niklas. An ion treatment planning framework for inclusion of nanodosimetric ionization detail through cluster dose.. Medical physics. 2026. DOI: 10.1002/mp.70579.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.