MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2024.05.022

Медицинская библиотека · Annals of vascular surgery · 2024

Multicenter CT Image-Based Anatomic Assessment of Patients with Aortoiliac Aneurysm Undergoing Endovascular Repair with Iliac Branch Devices.

Panthofer Annalise, Bresler Alina-Marilena, Olson Sydney L, Kuramochi Yuki, Eagleton Matthew, Böckler Dittmar, Schneider Darren B, Lyden Sean P, Blackwelder William C, Meadows Wendy, Pauli Tom, DeRoo Elise, Matsumura Jon S

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The Global Iliac Branch Study (NCT05607277) is an international, multicenter, retrospective cohort study of anatomic predictors of adverse iliac events (AIEs) in aortoiliac aneurysms treated with iliac branch devices (IBDs).

METHODS

Patients with pre-IBD and post-IBD computed tomography imaging were included. We measured arterial diameters, stenosis, calcification, bifurcation angles, and tortuosity indices using a standardized, validated protocol. A composite of ipsilateral AIE was defined, a priori, as occlusion, type I or III endoleak, device constriction, or clinical event requiring reintervention. Paired t-test compared tortuosity indices and splay angles pretreatment and post-treatment for all IBDs and by device material (stainless steel and nitinol). Two-sample t-test compared anatomical changes from pretreatment to post-treatment by device material. Logistic regression assessed associations between AIE and anatomic measurements. Analysis was performed by IBD.

RESULTS

We analyzed 297 patients (286 males, 11 females) with 331 IBDs (227 stainless steel, 104 nitinol). Median clinical follow-up was 3.8 years. Iliac anatomy was significantly straightened with all IBD treatment, though stainless steel IBDs had a greater reduction in total iliac artery tortuosity index and aortic splay angle compared to nitinol IBDs (absolute reduction -0.20 [-0.22 to -0.18] vs. -0.09 [-0.12 to -0.06], P < 0.0001 and -19.6° [-22.4° to -16.9°] vs. -11.2° [-15.3° to -7.0°], P = 0.001, respectively). There were 54 AIEs in 44 IBDs in 42 patients (AIE in 13.3% of IBD systems), requiring 35 reinterventions (median time to event 41 days; median time to reintervention 153 days). There were 18 endoleaks, 29 occlusions, and 5 device constrictions. There were no strong associations between anatomic measurements and AIE overall, though internal iliac diameter was inversely associated with AIE in nitinol devices (nAIE, nitinol = 8).

CONCLUSIONS

Purpose-built IBDs effectively treat aortoiliac disease, including that with tortuous anatomy, with a high patency rate (91.5%) and low reintervention rate (9.1%) at 4 years. Anatomic predictors of AIE are limited.

Для цитирования: Panthofer Annalise, Bresler Alina-Marilena, Olson Sydney L, Kuramochi Yuki, Eagleton Matthew, Böckler Dittmar, Schneider Darren B, Lyden Sean P, Blackwelder William C, Meadows Wendy, Pauli Tom, DeRoo Elise, Matsumura Jon S. Multicenter CT Image-Based Anatomic Assessment of Patients with Aortoiliac Aneurysm Undergoing Endovascular Repair with Iliac Branch Devices.. Annals of vascular surgery. 2024. DOI: 10.1016/j.avsg.2024.05.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.