MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-016-0200-0

Медицинская библиотека · International ophthalmology · 2016

A retrospective analysis of vision correction and safety in keratoconus patients wearing Toris K soft contact lenses.

Sultan Pinar, Dogan Cezmi, Iskeleli Guzin

СтатьяПеревод пока не подготовлен

Аннотация

The purpose of this study was to investigate the efficacy and safety of the Toris K silicone hydrogel contact lens (SwissLens; Prilly, Switzerland) in keratoconus patients. A database with information on 50 keratoconus patients (64 eyes) fitted with Toris K soft contact lenses over a 2-year period was retrospectively reviewed. Demographic data, prefitting refraction, the reason for choosing the Toris K soft contact lens, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), best-corrected visual acuity with a rigid gas permeable lens (BCVA RGP), best-corrected visual acuity with the Toris K lens (BCVA Toris K), and complications were evaluated. The mean age ± standard deviation at the time of fitting was 27.92 ± 9.86 years. The mean spherical refractive power was -4.62 ± 6.53 dioptres, and the mean cylinder was -3.78 ± 2.43 dioptres. The most common reason for using Toris K soft contact lenses was an inability to fit the patient with a RGP contact lens. There was a statistically significant difference between UCVA and BCVA Toris K (p = 0.0001), as well as between BSCVA and BCVA Toris K (p = 0.0001). However, there was no statistically significant difference between BCVA Toris K and BCVA RGP (p = 0.20). Superficial punctate keratitis and giant papillary conjunctivitis were the most common complications. The Toris K contact lens is a viable alternative for the optical management of all grades of keratoconus. The Toris K soft contact lens is a promising alternative for the visual rehabilitation of keratoconus patients who cannot tolerate RGP lenses or achieve a good fit.

Для цитирования: Sultan Pinar, Dogan Cezmi, Iskeleli Guzin. A retrospective analysis of vision correction and safety in keratoconus patients wearing Toris K soft contact lenses.. International ophthalmology. 2016. DOI: 10.1007/s10792-016-0200-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.