MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000000709

Медицинская библиотека · Cornea · 2016

Comparison of Results of Accelerated Corneal Cross-Linking With Hypo-Osmolar Riboflavin Solution Performed on Corneas Thicker and Thinner Than 400 μm.

Koç Mustafa, Uzel Mehmet Murat, Koban Yaran, Durukan Irfan, Tekin Kemal, Ylmazbaş Pelin

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the effect of accelerated corneal cross-linking (CXL) according to corneal thickness in keratoconus.

METHODS

Patients undergoing corneal CXL (9 mW/cm(2)) with hypo-osmolar riboflavin solution were included in this study. The patients were divided into 2 groups. Group 1 included patients with corneal thickness below 400 μm (50 eyes from 45 patients), and group 2 included patients with corneal thickness above 400 μm (50 eyes from 47 patients). Visual acuity (VA), refraction, topographic values, and higher-order aberrations were evaluated in the preoperative term and postoperatively at months 1, 3, and 6.

RESULTS

The improvements in VA were significant and similar in both groups [0.25/0.19 logMAR, P = 0.130]. In group 1, the rate of decrease in spherical refraction [0.85/0.27 diopters (D), P = 0.012] and maximum keratometry (Kmax, 2.49/0.68 D, P < 0.001) was significantly higher than that in group 2. The cylindrical change was similar (0.43/0.29 D P = 0.173). Corneal thinning was higher in group 2 (25/40.4 μm P < 0.001). Anterior elevation values decreased at higher rates in group 1 (3.73/0.24 μm P < 0.001); neither group showed a significant difference in posterior elevation (-0.14/-0.4 μm P > 0.05). In group 1, all aberration values except trefoil significantly decreased, whereas in group 2 none of the aberrations decreased except the total root mean square. All higher-order aberration values decreased at significantly higher rates in group 1 (P < 0.05).

CONCLUSIONS

In thin corneas, accelerated corneal CXL provides better anatomical changes; however, the improvement in VA is similar to that in thick corneas.

Для цитирования: Koç Mustafa, Uzel Mehmet Murat, Koban Yaran, Durukan Irfan, Tekin Kemal, Ylmazbaş Pelin. Comparison of Results of Accelerated Corneal Cross-Linking With Hypo-Osmolar Riboflavin Solution Performed on Corneas Thicker and Thinner Than 400 μm.. Cornea. 2016. DOI: 10.1097/ico.0000000000000709.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.