Analysis of dose distribution reproducibility based on a fluence map of in vivo transit dose using an electronic portal imaging device.

Tardi Didin, Fitriandini Aninda, Fauziah Annisa Rahma, Wibowo Wahyu Edy, Siswantining Titin, Pawiro Supriyanto Ardjo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Morphological changes can affect distribution of dose in patients. Determination of the dose distribution changes for each fraction radiotherapy can be done by relativein vivodosimetry (IVD). This study analysed the distribution of doses per fraction based on the fluence map recorded by the electronic portal imaging device (EPID) of the patient's transit dose. This research examined cases involving the cervix, breast, and nasopharynx. Transit dose analysis was performed by calculating the gamma index (GI) with composite and field-by-field methods. The gamma passing rate (GPR) value was assessed for its correlation with the subject's body weight. In the case of the nasopharynx, breast, and cervix, the GPR value decreased as the fraction increased. In the case of the nasopharynx, the correlation between the GPR and fraction radiotherapy showed no difference when using either composite or field-by-field methods. However, in cases involving the cervix and breast, there was a difference in the correlation values between the composite and field-by-field methods, where the subject had a significant correlation (p< 0.05) when it was done using a field-by-field method. In addition, the nasopharynx had the highest number of subjects with significant correlation (p< 0.05) between GPR and body weight, followed by the cervix and breast. In the nasopharynx, breast, and cervix, the reproducibility of the dose distribution decreased. This decreased reproducibility was associated with changes in body weight.

Для цитирования: Tardi Didin, Fitriandini Aninda, Fauziah Annisa Rahma, Wibowo Wahyu Edy, Siswantining Titin, Pawiro Supriyanto Ardjo. Analysis of dose distribution reproducibility based on a fluence map of in vivo transit dose using an electronic portal imaging device.. Biomedical physics & engineering express. 2023. DOI: 10.1088/2057-1976/ad124a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.