Estimating Total Corneal Astigmatism From Anterior Corneal Data.

Næser Kristian, Savini Giacomo, Bregnhøj Jesper Flethøj

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To determine keratometric astigmatism (KA), posterior corneal astigmatism (PCA), and total corneal astigmatism (TCA) in 951 normal eyes, to establish a model for estimating TCA from anterior corneal data, and to test this method in a new group of eyes with toric intraocular lenses (TIOLs).

METHODS

We used a Pentacam HR (high-resolution) Scheimpflug camera to determine KA, PCA, and TCA in 951 normal eyes. A model to estimate TCA from anterior corneal data was evaluated by the difference (=error) between the measured TCA and the estimated value. The model was tested in 40 eyes with TIOLs.

RESULTS

KA, TCA, and PCA averaged 1.06 (±0.85) D, 1.05 (±0.83) D, and 0.33 (±0.17) D. The error of the model to estimate TCA averaged zero with an SD of ±0.21 D. Application of this model and of direct Pentacam TCA measurements in TIOL calculation gave similar results, namely a slight reduction of overcorrection in with-the-rule astigmatism, but an eradication of undercorrection in against-the-rule astigmatism.

CONCLUSIONS

It was possible to estimate TCA accurately from anterior corneal data with a new formula. However, application of both this model on keratometric data and of direct Pentacam measurements in a group of 40 eyes with TIOLs did not completely eradicate the refractive error in TIOL calculation. More studies comparing Pentacam TCA and refractive astigmatism are required.

Для цитирования: Næser Kristian, Savini Giacomo, Bregnhøj Jesper Flethøj. Estimating Total Corneal Astigmatism From Anterior Corneal Data.. Cornea. 2017. DOI: 10.1097/ico.0000000000001224.