MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/ch-151986

Медицинская библиотека · Clinical hemorheology and microcirculation · 2015

Evaluation of multimodality imaging using image fusion with MRI and CEUS in an experimental animal model.

Paprottka P M, Zengel P, Cyran C C, Paprottka K J, Ingrisch M, Nikolaou K, Reiser M F, Clevert D A

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the diagnostic benefits of multimodality imaging using image fusion with magnetic-resonance-imaging (MRI) and contrast-enhanced-ultrasound (CEUS) in an experimental small-animal-squamous-cell-carcinoma-model for the assessment of tissue hemodynamics and morphology.

MATERIAL AND

METHODS

Human hypopharynx-carcinoma-cells were injected subcutaneously into the left flank of 15 female athymic nude rats. After 10 daysof subcutaneous tumor growth, CEUS and MRI measurements were performed using a high-end-ultrasound-system and 3-T-MRI. After successful point-to-point or plan registration, the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologists using a subjective 5-point scale.

RESULTS

CEUS and MRI are well-known techniques for the assessment of tissue hemodynamics (score: mean 3.8 ± 0.4 SD and score 3.8 ± 0.4 SD). Real-time image fusion of MRI and CEUS yielded a significant (p <  0.001) improvement in score (score 4.8 ± 0.4 SD). Reliable detection of small necrotic areas was possible in all animals with necrotic tumors. No significant intraobserver and interobserver variability was detected (kappa coefficient = +1).

CONCLUSION

Image fusion of MRI and CEUS gives a significant improvement for reliable differentiation between different tumor tissue areas and simplifies investigations by showing the morphology as well as surrounding macro-/microvascularization.

Для цитирования: Paprottka P M, Zengel P, Cyran C C, Paprottka K J, Ingrisch M, Nikolaou K, Reiser M F, Clevert D A. Evaluation of multimodality imaging using image fusion with MRI and CEUS in an experimental animal model.. Clinical hemorheology and microcirculation. 2015. DOI: 10.3233/ch-151986.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.