MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2016.09.032

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2016

The Effect of Transesophageal Echocardiography Probe Placement on Intracuff Pressure of an Endotracheal Tube in Infants and Children.

Kamata Mineto, Hakim Mumin, Tumin Dmitry, Krishna Senthil G, Naguib Aymen, Tobias Joseph D

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the effects of transesophageal echocardiography (TEE) probe insertion on the endotracheal cuff pressure (CP).

DESIGN

Prospective observational study.

SETTING

Single standing, not-for-profit pediatric hospital.

PARTICIPANTS

A total of 80 pediatric patients (aged 6 days to 18.4 years) who underwent cardiac surgery and intraoperative TEE.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN

RESULTS

Following anesthesia induction and endotracheal intubation, the CP was recorded at 4 points: before the insertion of the TEE (P1), at TEE insertion (P2), during TEE examination (P3), and after the probe was advanced into the stomach (P4). Twenty patients were enrolled in each of the following age groups:<1 year of age; 1-4 years of age; 5-8 years of age; and 9-18 years of age. CP was compared between pairs of time points using paired t-tests, and differences in CP over time were compared among age groups using repeated-measures analysis of variance. CP at P1, P2, P3, and P4 was 18.7±11.6, 26.7±14.4, 22.3±12.4, and 20.6±12.6 cmH2O, respectively. Although CP significantly increased from P1 to P2 (p<0.001), there was no significant difference between P1 and P4 (95% CI; -0.3 to 4.1; p = 0.083). There was no significant difference in CP change based on the age of the patient.

CONCLUSION

Following a transient increase in CP with TEE probe insertion, the CP returned to baseline after the tip of the TEE probe was advanced into the stomach. There was no variation among age groups in the magnitude of the CP change during the study.

Для цитирования: Kamata Mineto, Hakim Mumin, Tumin Dmitry, Krishna Senthil G, Naguib Aymen, Tobias Joseph D. The Effect of Transesophageal Echocardiography Probe Placement on Intracuff Pressure of an Endotracheal Tube in Infants and Children.. Journal of cardiothoracic and vascular anesthesia. 2016. DOI: 10.1053/j.jvca.2016.09.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.