m+Medelevator.RU
← Поиск публикаций
Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2000

99mTc-PEG liposomes for the scintigraphic detection of infection and inflammation: clinical evaluation.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dams E T, Oyen W J, Boerman O C, Storm G, Laverman P, Kok P J, Buijs W C, Bakker H, van der Meer J W, Corstens F H

Аннотация

UNLABELLED: Polyethyleneglycol (PEG) liposomes have been shown to be excellent vehicles for scintigraphic imaging of infection and inflammation in various experimental models. In this article we report on a series of patients with possible infectious and inflammatory disease in whom the performance of 99mTc-PEG liposomes was evaluated. The results of 99mTc-PEG liposome scintigraphy were directly compared with those of 111In-immunoglobulin G (IgG) scintigraphy.

METHODS: Thirty-five patients (22 men, 13 women; mean age, 51 y; range, 20-76 y), suspected of having infectious or inflammatory disease, received 740 MBq 99mTc-PEG liposomes intravenously. Imaging was performed at 4 and 24 h after injection. Patients received 75 MBq 111In-IgG 24 h after administration of the liposomes. The scintigraphic results were compared and verified by culture, biopsy, surgery, and follow-up of at least 6 mo.

RESULTS: Of the 16 proven infections and inflammations, 15 were detected by 99mTc-PEG liposome scintigraphy: soft-tissue infection (n = 3), septic arthritis (n = 3), autoimmune polyarthritis (n = 2), infected hip prosthesis (n = 1), infected osteosynthesis (n = 1), spondylodiscitis (n = 1), infected aortic prosthesis (n = 1), colitis (n = 1), abdominal abscess (n = 1), and pneumonia (n = 1). 99mTc-PEG liposome and 111In-IgG scintigraphy both missed 1 case of endocarditis. In addition, an 111In-IgG scan of a patient with mild soft-tissue infection was false-negative. Concordantly false-positive scans were recorded from 2 patients, both with uninfected pseudarthrosis and focal signs of sterile inflammation. During liposomal administration, 1 patient experienced flushing and chest tightness, which rapidly disappeared after lowering the infusion rate. No other adverse events were observed.

CONCLUSION: This clinical evaluation of 99mTc-PEG liposomes shows that focal infection and inflammation can be adequately imaged with this new agent. The performance of 99mTc-PEG liposomes is at least as effective as that of 111In-IgG. With the simple and safe preparation and the physical and logistic advantages of a 99mTc label, 99mTc-PEG liposomes could be an attractive agent for infection or inflammation imaging.