MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/2057-1976/ad6a64

Медицинская библиотека · Biomedical physics & engineering express · 2024

An end-to-end deep learning pipeline to derive blood input with partial volume corrections for automated parametric brain PET mapping.

Chavan Rugved, Hyman Gabriel, Qureshi Zoraiz, Jayakumar Nivetha, Terrell William, Wardius Megan, Berr Stuart, Schiff David, Fountain Nathan, Eluvathingal Muttikkal Thomas, Quigg Mark, Zhang Miaomiao, Kundu Bijoy K

СтатьяПеревод пока не подготовлен

Аннотация

Dynamic 2-[18F] fluoro-2-deoxy-D-glucose positron emission tomography (dFDG-PET) for human brain imaging has considerable clinical potential, yet its utilization remains limited. A key challenge in the quantitative analysis of dFDG-PET is characterizing a patient-specific blood input function, traditionally reliant on invasive arterial blood sampling. This research introduces a novel approach employing non-invasive deep learning model-based computations from the internal carotid arteries (ICA) with partial volume (PV) corrections, thereby eliminating the need for invasive arterial sampling. We present an end-to-end pipeline incorporating a 3D U-Net based ICA-net for ICA segmentation, alongside a Recurrent Neural Network (RNN) based MCIF-net for the derivation of a model-corrected blood input function (MCIF) with PV corrections. The developed 3D U-Net and RNN was trained and validated using a 5-fold cross-validation approach on 50 human brain FDG PET scans. The ICA-net achieved an average Dice score of 82.18% and an Intersection over Union of 68.54% across all tested scans. Furthermore, the MCIF-net exhibited a minimal root mean squared error of 0.0052. The application of this pipeline to ground truth data for dFDG-PET brain scans resulted in the precise localization of seizure onset regions, which contributed to a successful clinical outcome, with the patient achieving a seizure-free state after treatment. These results underscore the efficacy of the ICA-net and MCIF-net deep learning pipeline in learning the ICA structure's distribution and automating MCIF computation with PV corrections. This advancement marks a significant leap in non-invasive neuroimaging.

Для цитирования: Chavan Rugved, Hyman Gabriel, Qureshi Zoraiz, Jayakumar Nivetha, Terrell William, Wardius Megan, Berr Stuart, Schiff David, Fountain Nathan, Eluvathingal Muttikkal Thomas, Quigg Mark, Zhang Miaomiao, Kundu Bijoy K. An end-to-end deep learning pipeline to derive blood input with partial volume corrections for automated parametric brain PET mapping.. Biomedical physics & engineering express. 2024. DOI: 10.1088/2057-1976/ad6a64.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.