MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-023-05303-9

Медицинская библиотека · Clinical oral investigations · 2023

The influence of implant position and of prosthetic characteristics on the occurrence of peri-implantitis: a retrospective study on periapical radiographs.

Corbella Stefano, Morandi Benedetta, Calciolari Elena, Alberti Alice, Francetti Luca, Donos Nikolaos

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The present retrospective study aimed to investigate the influence of malposition on the occurrence of peri-implantitis.

MATERIALS AND

METHODS

The study included clinical records of systemically healthy patients with single and partial implant-supported rehabilitations and at least 1-year post-loading follow-up. The parameters collected included implant-related factors, patient-related factors, site-related factors, and prosthesis-related factors. The radiographic measurements were taken by using a dedicated software and the diagnosis of peri-implantitis was made based on all the available clinical and radiographic data. Descriptive statistics were provided for all variables. Following an exploratory approach, an implant-level analysis of factors influencing the occurrence of peri-implantitis was done through a multilevel multivariate logistic regression (mixed).

RESULTS

A total of 180 implants belonging to 90 subjects were randomly selected. Malposition showed no statistically significant association with the occurrence of peri-implantitis. According to the multi-level analysis, the parameters that were significantly associated with peri-implantitis included presence / history of periodontitis (OR = 5.945, 95% CI: 1.093 - 32.334, P = 0.039) and presence of an emergence profile angle ≥ 45° (OR = 9.094, 95% CI: 2.017 - 40.995, P = 0.005).

CONCLUSIONS

Implant malposition, as defined following Buser's criteria (2004), did not influence the occurrence of peri-implantitis in the selected cohort. Conversely, history of periodontitis and presence of a prosthetic emergence profile with an angle ≥ 45° were correlated to an increased risk of peri-implantitis.

Для цитирования: Corbella Stefano, Morandi Benedetta, Calciolari Elena, Alberti Alice, Francetti Luca, Donos Nikolaos. The influence of implant position and of prosthetic characteristics on the occurrence of peri-implantitis: a retrospective study on periapical radiographs.. Clinical oral investigations. 2023. DOI: 10.1007/s00784-023-05303-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.