BMC musculoskeletal disorders · 2025
Radiographic identification method of safe medial pinning zone and its clinical efficacy in pediatric supracondylar humeral fracture fixation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Liu Hongbin, Zhu Yong, Hu Yi, Li Kaihu, Long Haitao, Lin Zhangyuan, Zhao Ruibo, Sun Buhua, Zhao Shushan, Cheng Liang
Аннотация
OBJECTIVES: Preventing iatrogenic ulnar nerve injury remains a critical challenge during medial pinning in pediatric supracondylar humeral fractures (SCHFs). This study seeks to define a safe zone for medial pin insertion and evaluate its effectiveness in minimizing complications.
METHODS: Three-dimensional reconstructions of radiographs from a healthy elbow joint were generated using E3d software to delineate a safe medial pinning zone. Pediatric patients with modified Gartland type III or IV SCHFs who underwent closed reduction and percutaneous crossed pin fixation were categorized into two groups based on the medial pin entry point observed via intraoperative fluoroscopy. A retrospective analysis was performed to assess the safety and effectiveness of pin placement. Furthermore, in a case of postoperative ulnar nerve dysfunction, the standard medial pinning technique was replaced with the defined safe entry approach.
RESULTS: On the anteroposterior (AP) view, the upper segment of the oblique line was identified as the safe zone, as the ulnar nerve lies within the groove at the lower segment. On the lateral view, a diamond-shaped area was confirmed as the safe insertion zone for medial pinning. The study included 134 SCHF cases, divided into group A (74 cases), where medial Kirschner wire (K-wire) placement was within the defined safe zones in both views, and group B (60 cases), where placement occurred outside these zones. The incidence of ulnar nerve injury in group A was significantly lower than in group B (P = 0.0324). Additionally, exploration and neurolysis were performed in cases of postoperative ulnar nerve dysfunction. A left-handed maneuver during surgery was found to aid in the precise identification of the safe entry site for medial pinning.
CONCLUSIONS: Medial pinning performed within the delineated safe zone, with guidance from intraoperative fluoroscopy, significantly reduces the likelihood of iatrogenic ulnar nerve injury in pediatric SCHF patients.
LEVEL OF EVIDENCE: Level III retrospective comparative study.
METHODS: Three-dimensional reconstructions of radiographs from a healthy elbow joint were generated using E3d software to delineate a safe medial pinning zone. Pediatric patients with modified Gartland type III or IV SCHFs who underwent closed reduction and percutaneous crossed pin fixation were categorized into two groups based on the medial pin entry point observed via intraoperative fluoroscopy. A retrospective analysis was performed to assess the safety and effectiveness of pin placement. Furthermore, in a case of postoperative ulnar nerve dysfunction, the standard medial pinning technique was replaced with the defined safe entry approach.
RESULTS: On the anteroposterior (AP) view, the upper segment of the oblique line was identified as the safe zone, as the ulnar nerve lies within the groove at the lower segment. On the lateral view, a diamond-shaped area was confirmed as the safe insertion zone for medial pinning. The study included 134 SCHF cases, divided into group A (74 cases), where medial Kirschner wire (K-wire) placement was within the defined safe zones in both views, and group B (60 cases), where placement occurred outside these zones. The incidence of ulnar nerve injury in group A was significantly lower than in group B (P = 0.0324). Additionally, exploration and neurolysis were performed in cases of postoperative ulnar nerve dysfunction. A left-handed maneuver during surgery was found to aid in the precise identification of the safe entry site for medial pinning.
CONCLUSIONS: Medial pinning performed within the delineated safe zone, with guidance from intraoperative fluoroscopy, significantly reduces the likelihood of iatrogenic ulnar nerve injury in pediatric SCHF patients.
LEVEL OF EVIDENCE: Level III retrospective comparative study.