m+Medelevator.RU
← Поиск публикаций
Journal of shoulder and elbow surgery · 2013

Large metaphyseal volume hemiprostheses for complex fractures of the proximal humerus.

Оценочное исследованиеСтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fucentese Sandro F, Sutter Reto, Wolfensperger Fabian, Jost Bernhard, Gerber Christian

Аннотация

BACKGROUND: Results of hemiarthroplasty after acute complex proximal humerus fractures are controversial. The main problem is the fixation and healing of the greater tuberosity (GT). To address this problem a hemiarthroplasty with a large metaphyseal volume was designed and introduced.

METHODS: Thirty hemiarthroplasties were implanted for acute, complex, proximal humeral fractures in 30 consecutive patients (average age: 63.3 years; range, 41-78). One patient was lost; 2 patients could only be interviewed telefonically. Two patients had to be revised because of secondary displacement of the GT within the first 2 postoperative years. The remaining 25 patients were assessed clinically, radiographically, and with computer tomography (CT) imaging after a mean of 25 months (range, 24-29).

RESULTS: Greater tuberosity healed in situ in 23 patients. In 12 cases, CT documented severe resorption of GT without displacement of a measurable bone fragment and an intact clinical cuff function with a radiographically preserved acromio-humeral distance. The mean Constant score was 59 points (range, 26-81), the mean relative Constant score 75% (range, 31-100). The mean anterior elevation was 117° (range, 45-160). The mean subjective shoulder value was 70% (range, 25-98). In 4 cases (14%), tuberosity dislocation occurred which was associated with an increase of fatty infiltration and poor result.

CONCLUSION: The 2-year results with a large metaphyseal volume fracture-prosthesis showed good to excellent results, with a failure rate of 14%. Substantial resorption of the greater tuberosity was frequent, but was not associated with functional incompetence of the rotator cuff. The overall results obtained justify its continued use.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты