MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2015.01.015

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2015

Can retinoscopy keep up in keratoconus diagnosis?

Goebels Susanne, Käsmann-Kellner Barbara, Eppig Timo, Seitz Berthold, Langenbucher Achim

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the diagnostic potential of retinoscopy in comparison with Amsler-grading, Pentacam and Ocular Response Analyzer (ORA) in classifying keratoconus stages.

METHODS

Clinical examination, retinoscopy, Pentacam and ORA were performed in 126 patients. Data of Amsler, retinoscopy, topographic keratoconus classification (TKC) of Pentacam and keratoconus match probability (KMP) of ORA were analyzed. Each of these four classification techniques quotes keratoconus into stage 0 (normal) to 4 (severe). Descriptive analysis and cross tables were used to compare the different devices.

RESULTS

For retinoscopy the distribution in the five keratoconus grades normal/suspect/mild/moderate/severe (in numbers) was 34/33/34/17/8. For Amsler it was 37/36/35/12/4, for TKC 38/17/34/31/4, for KMP 32/34/32/15/9. The cross tables show large classification differences of all devices. Overall, classification of retinoscopy and Amsler/TKC/KMP is congruent in 51.6%/36.3%/39.8% of the cases. Of all eyes, Amsler was congruent with TKC/KMP in 54.0%/48.4%, and TKC and KMP were congruent in 53.3%. In a binary decision (normal vs. any stage of mild/moderate/severe) matching between retinoscopy and Amsler/TKC/KMP was 98.6%/88.8%/82.4%. Sensitivity/specificity for retinoscopy and Amsler, TKC, KMP was 98.8%/94.0%, 84.4%/100% and 80.0%/79.1%.

CONCLUSIONS

The congruence of keratoconus classification was very poor of all the techniques tested in our study. This applies to objective measures such as TKC, KMP as well as clinical classification techniques such as Amsler and retinoscopy. Compared to TKC and KMP, retinoscopy underestimates keratoconus stages. In contrast, the performance of binary decisions (normal vs. keratoconus) shows a high sensitivity and specificity. Retinoscopy, however, showed a clear clinical use in confirming the diagnosis of keratoconus.

Для цитирования: Goebels Susanne, Käsmann-Kellner Barbara, Eppig Timo, Seitz Berthold, Langenbucher Achim. Can retinoscopy keep up in keratoconus diagnosis?. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2015. DOI: 10.1016/j.clae.2015.01.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.