MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2008.02.001

Медицинская библиотека · The Annals of thoracic surgery · 2008

Pulmonary valve replacement: a comparison of three biological valves.

Fiore Andrew C, Rodefeld Mark, Turrentine Mark, Vijay Palaniswamy, Reynolds Tyler, Standeven John, Hill Kirstin, Bost Jamie, Carpenter Dustin, Tobin Courtney, Brown John W

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

We retrospectively reviewed the performance of the mosaic porcine, bovine pericardial, and homograft prostheses for pulmonary valve replacement to correct chronic pulmonary insufficiency.

METHODS

From January 1995 to August 2006, 82 patients (mean age, 22.7 years) underwent valve replacement with porcine (49 patients), bovine pericardial (18 patients), or pulmonary homograft (15 patients) prosthesis at a mean of 15.3 years after initial outflow tract reconstruction. Excluded were patients with extracardiac conduits, monocusp valves, or the Ross procedure. The groups were similar with respect to age, body surface area, degree of regurgitation, right ventricular dimension, right ventricular to pulmonary artery gradient, and valve size. Follow-up was longer in the homograft cohort (porcine, 20 +/- 27 months; pericardial, 42 +/- 21; homograft, 49 +/- 40; p < 0.01).

RESULTS

All three prostheses significantly reduce chronic pulmonary regurgitation, but late insufficiency was higher with homografts. Right ventricular dimension was significantly reduced in the stented but not the allograft cohorts. Late valve dysfunction was highest with homografts (54%), followed by porcine (19%) and pericardial valves (5.5%; p < 0.05. Functional class and mild to moderate tricuspid insufficiency significantly improved with pulmonary valve replacement. Early and late mortality was 3.6% and 1.2%, respectively.

CONCLUSIONS

All three prostheses performed similarly for 3 years. Pulmonary regurgitation developed more frequently in homografts albeit at a longer duration of follow-up.

Для цитирования: Fiore Andrew C, Rodefeld Mark, Turrentine Mark, Vijay Palaniswamy, Reynolds Tyler, Standeven John, Hill Kirstin, Bost Jamie, Carpenter Dustin, Tobin Courtney, Brown John W. Pulmonary valve replacement: a comparison of three biological valves.. The Annals of thoracic surgery. 2008. DOI: 10.1016/j.athoracsur.2008.02.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.