MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/eye.2013.116

Медицинская библиотека · Eye (London, England) · 2013

Changes in choroidal thickness, axial length, and ocular perfusion pressure accompanying successful glaucoma filtration surgery.

Kara N, Baz O, Altan C, Satana B, Kurt T, Demirok A

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the changes in choroidal thickness (CT), axial length (AL), and ocular perfusion pressure (OPP) accompanying intraocular pressure (IOP) reduction after trabeculectomy. methods: Thirty-nine eyes of 39 patients with primary open-angle glaucoma uncontrolled by medical therapy were included in this prospective and interventional study. All patients underwent a fornix-based trabeculectomy. The CT was measured by enhanced depth imaging-optical coherence tomography. IOP, AL, and systolic/diastolic blood pressure were also measured, and OPP was calculated. All measurements were performed at baseline and 1 month after surgery.

RESULTS

The mean IOP was 25.0 ± 5.8 mm Hg at baseline and 11.7 ± 2.6 mm Hg after trabeculectomy (P<0.001), and the mean subfoveal CT was 295 ± 84 mm Hg at baseline and 331 ± 82 mm Hg after trabeculectomy (P<0.001). The mean AL was 23.64 ± 0.98 mm at baseline and 23.54 ± 0.96 mm after trabeculectomy (P<0.001), whereas the mean OPP was 38.8 ± 6.2 mm Hg preoperatively, and 51.1 ± 7.3 mm Hg postoperatively (P<0.001). The change in CT negatively correlated with the change in IOP (r=-0.785, P<0.001) and AL (r=-0.693, P<0.001), whereas it positively correlated with the change in OPP (r=0.418, P=0.008).

CONCLUSION

These results suggest that the large IOP decrease following trabeculectomy causes choroidal thickening. In addition, CT changes are associated with IOP and AL reduction as well as OPP increase.

Для цитирования: Kara N, Baz O, Altan C, Satana B, Kurt T, Demirok A. Changes in choroidal thickness, axial length, and ocular perfusion pressure accompanying successful glaucoma filtration surgery.. Eye (London, England). 2013. DOI: 10.1038/eye.2013.116.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.