MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iae.0000000000003981

Медицинская библиотека · Retina (Philadelphia, Pa.) · 2024

PREVALENCE AND CLINICAL FEATURES OF RADIAL FUNDUS AUTOFLUORESCENCE IN HIGH MYOPIC WOMEN.

Wang Shih-Wen, Igarashi-Yokoi Tae, Mochida Shiho, Fujinami Kaoru, Ohno-Matsui Kyoko

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the prevalence and characteristics of radial fundus autofluorescence (FAF) in highly myopic women.

METHODS

This was a retrospective, observational case study to determine the prevalence of radial FAF in the ultra-widefield FAF images in women. The clinical characteristics of these patients were evaluated.

RESULTS

Fifteen of 1,935 (0.78%) highly myopic women were found to have radial FAF. Their mean age was 36.6 ± 25.6 years, and their mean best-corrected visual acuity was 0.3 ± 0.42 logMAR units. The mean axial length (AL) was 28.8 ± 2.8 mm. Among the 15 cases, eight did not have pigmentary changes and seven had pigmentary changes in the ultra-widefield FAF images. The women with the pigmentary changes were significantly older ( P = 0.021), had poorer BCVA ( P = 0.001), and had longer ALs ( P = 0.002). The visual fields and electroretinograms were worse in the eyes with pigmentary changes.

CONCLUSION

The prevalence of radial FAF was 0.78% in women with high myopia. These patients might have mutations in the RPGR or RP2 genes and can develop high myopia and retinitis pigmentosa. Ultra-widefield FAF images should be examined in all highly myopic patients for early detection of radial FAF, and myopia prevention and genetic counseling for possible genetic therapy are recommended.

Для цитирования: Wang Shih-Wen, Igarashi-Yokoi Tae, Mochida Shiho, Fujinami Kaoru, Ohno-Matsui Kyoko. PREVALENCE AND CLINICAL FEATURES OF RADIAL FUNDUS AUTOFLUORESCENCE IN HIGH MYOPIC WOMEN.. Retina (Philadelphia, Pa.). 2024. DOI: 10.1097/iae.0000000000003981.