MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2016.01.005

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2016

Corneal elevation in a large number of myopic Chinese patients.

Ying Jinglu, Wang Qinmei, Belin Michael W, Wan Ting, Lin Shishi, Feng Yifan, Gao Rongrong, Huang Jinhai

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To establish a normative database for corneal elevation in Chinese myopic patients who underwent refractive surgery, and analyze the association of corneal elevation with sex, age, and ocular parameters.

METHODS

A total of 3000 eyes in 1500 patients were evaluated with the Pentacam. Anterior and posterior elevations were measured at the apex and thinnest point. Normative thresholds were defined according to the Tukey method. Univariate and multivariate analyses were performed to assess the association of corneal elevation with sex, age, and ocular parameters.

RESULTS

Normal upper limits for corneal elevation in adult Chinese were 4.95μm, 5.25μm, 6.2μm, and 11.0μm at the anterior apex, anterior thinnest point, posterior apex, and posterior thinnest point, respectively. Thinner corneal pachymetry at the apex and greater anterior corneal astigmatism tended to show greater anterior corneal elevation values. Younger age, greater anterior corneal astigmatism, lower anterior and posterior keratometry, and shallower anterior chamber depth resulted in greater posterior corneal elevation values.

CONCLUSIONS

Locally derived thresholds may offer higher sensitivity and specificity when screening eyes for myopic refractive surgery, and keratoconic and post-orthokeratology eyes. Anterior and posterior corneal elevation at the apex and thinnest point were associated significantly with anterior corneal astigmatism, showing a positive correlation.

Для цитирования: Ying Jinglu, Wang Qinmei, Belin Michael W, Wan Ting, Lin Shishi, Feng Yifan, Gao Rongrong, Huang Jinhai. Corneal elevation in a large number of myopic Chinese patients.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2016. DOI: 10.1016/j.clae.2016.01.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.