MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.25947

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2015

Clinical and procedural impact of aortic arch anatomic variants in carotid stenting procedures.

Burzotta Francesco, Nerla Roberto, Pirozzolo Giancarlo, Aurigemma Cristina, Niccoli Giampaolo, Leone Antonio Maria, Saffioti Silvia, Crea Filippo, Trani Carlo

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the impact of aortic arch variants in patients undergoing carotid artery stenting (CAS).

BACKGROUND

CAS is increasingly carried out to treat the patients with internal carotid artery (ICA) stenosis. Aortic arch anatomy may influence its feasibility and affect clinical outcome.

METHODS

Aortic arch digital subtraction angiography was systematically performed before CAS. Aortic arch elongation and bovine arch variants were recorded. Catheter manipulation time (CMT) was assessed for each patient. Adverse cardiovascular and cerebral events were assessed at 30 days.

RESULTS

A total of 282 consecutive patients undergoing CAS under proximal balloon occlusion (57.8%) or distal filter (42.2%) neuroprotection were enrolled (age, 72 ± 7 years; 72.7% males). Type II and III elongation variants were detected in 23.4% and 10.6% of patients, respectively; in total, 20.5% of the patients had bovine configuration. CMT was significantly influenced by aortic elongation (56.1 ± 16.5 min in patients with type III aortic arch configuration compared to 38.2 ± 11.6 min in patients with type I or type II, P < 0.01) and (in left ICA) by bovine configuration (49.2 ± 11.4 min in bovine variants vs. 37.7 ± 11.5 min in patients with nonbovine anatomy, P < 0.001). CMT, but not aortic arch anatomy, resulted the only independent predictor of 30-day adverse outcome (hazard ratio [HR], 1.07; 95% confidence interval [CI], 1.03-1.10, P < 0.01).

CONCLUSIONS

Adverse aortic arch anatomies are frequently encountered in CAS procedures and are associated to longer procedural times. A longer CMT increases the risk for adverse outcome. These data suggest that a careful procedure planning aimed at a reduction of CMT may be pivotal to improve the safety of CAS procedures.

Для цитирования: Burzotta Francesco, Nerla Roberto, Pirozzolo Giancarlo, Aurigemma Cristina, Niccoli Giampaolo, Leone Antonio Maria, Saffioti Silvia, Crea Filippo, Trani Carlo. Clinical and procedural impact of aortic arch anatomic variants in carotid stenting procedures.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2015. DOI: 10.1002/ccd.25947.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.