MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1073/pnas.1001515107

Медицинская библиотека · Proceedings of the National Academy of Sciences of the United States of America · 2010

Microfluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays.

Saliba Antoine-Emmanuel, Saias Laure, Psychari Eleni, Minc Nicolas, Simon Damien, Bidard François-Clément, Mathiot Claire, Pierga Jean-Yves, Fraisier Vincent, Salamero Jean, Saada Véronique, Farace Françoise, Vielh Philippe, Malaquin Laurent, Viovy Jean-Louis

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

We propose a unique method for cell sorting, "Ephesia," using columns of biofunctionalized superparamagnetic beads self-assembled in a microfluidic channel onto an array of magnetic traps prepared by microcontact printing. It combines the advantages of microfluidic cell sorting, notably the application of a well controlled, flow-activated interaction between cells and beads, and those of immunomagnetic sorting, notably the use of batch-prepared, well characterized antibody-bearing beads. On cell lines mixtures, we demonstrated a capture yield better than 94%, and the possibility to cultivate in situ the captured cells. A second series of experiments involved clinical samples--blood, pleural effusion, and fine needle aspirates--issued from healthy donors and patients with B-cell hematological malignant tumors (leukemia and lymphoma). The immunophenotype and morphology of B-lymphocytes were analyzed directly in the microfluidic chamber, and compared with conventional flow cytometry and visual cytology data, in a blind test. Immunophenotyping results using Ephesia were fully consistent with those obtained by flow cytometry. We obtained in situ high resolution confocal three-dimensional images of the cell nuclei, showing intranuclear details consistent with conventional cytological staining. Ephesia thus provides a powerful approach to cell capture and typing allowing fully automated high resolution and quantitative immunophenotyping and morphological analysis. It requires at least 10 times smaller sample volume and cell numbers than cytometry, potentially increasing the range of indications and the success rate of microbiopsy-based diagnosis, and reducing analysis time and cost.

Для цитирования: Saliba Antoine-Emmanuel, Saias Laure, Psychari Eleni, Minc Nicolas, Simon Damien, Bidard François-Clément, Mathiot Claire, Pierga Jean-Yves, Fraisier Vincent, Salamero Jean, Saada Véronique, Farace Françoise, Vielh Philippe, Malaquin Laurent, Viovy Jean-Louis. Microfluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays.. Proceedings of the National Academy of Sciences of the United States of America. 2010. DOI: 10.1073/pnas.1001515107.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.