Field evaluation of a novel semi-quantitative point-of-care diagnostic for G6PD deficiency in Indonesia.

Sadhewa Arkasha, Panggalo Lydia V, Nanine Illene, Price Ric N, Thriemer Kamala, Satyagraha Ari W, Ley Benedikt

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The WHO recommends routine testing of G6PD activity to guide radical cure in patients with Plasmodium vivax malaria. Females may have intermediate G6PD enzyme activity and to date, only complex diagnostics are able to reliably identify them. The semi-quantitative G6PD diagnostic "One Step G6PD Test" (Humasis, RoK; "RDT") is a lateral flow assay that can distinguish deficient, intermediate, and normal G6PD status and offers a simpler diagnostic alternative.

METHODS

G6PD status of participants enrolled in Malinau and Nunukan Regencies and the capital Jakarta was assessed with the RDT, and G6PD activity was measured in duplicate by reference spectrophotometry. The adjusted male median (AMM) of the spectrophotometry measurements was defined as 100% activity; 70% and 30% of the AMM were defined as thresholds for intermediate and deficient G6PD status, respectively. Results were compared to those derived from spectrophotometry at the clinically relevant G6PD activity thresholds of 30% and 70%.

RESULTS

Of the 161 participants enrolled, 10 (6.2%) were G6PD deficient and 12 (7.5%) had intermediate G6PD activity by spectrophotometry. At the 30% threshold, the sensitivity of the RDT was 10.0% (95%CI: 0.3-44.5%) with a specificity of 99.3% (95%CI: 96.4-100.0%); the positive predictive value was 50.0% (95%CI: 1.3-98.7%) and the negative predictive value 94.3% (95%CI: 89.5-97.4%). The corresponding figures at the 70% threshold were 22.7% (95%CI: 7.8-45.4%), 100.0% (95%CI: 97.4-100.0%), 100.0% (95%CI: 47.8-100.0%) and 89.1% (95%CI: 83.1-93.5%), respectively.

CONCLUSION

While there is a dire need for an easy-to-use, economical, semi-quantitative diagnostic for the point of care, the observed performance of the "One Step G6PD Test" in its current form was insufficient to guide antimalarial treatment.

Для цитирования: Sadhewa Arkasha, Panggalo Lydia V, Nanine Illene, Price Ric N, Thriemer Kamala, Satyagraha Ari W, Ley Benedikt. Field evaluation of a novel semi-quantitative point-of-care diagnostic for G6PD deficiency in Indonesia.. PloS one. 2024. DOI: 10.1371/journal.pone.0301506.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.