MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2337/db23-0550

Медицинская библиотека · Diabetes · 2024

Improved Specificity of Glutamate Decarboxylase 65 Autoantibody Measurement Using Luciferase-Based Immunoprecipitation System Assays.

Wyatt Rebecca C, Grace Sian L, Brigatti Cristina, Marzinotto Ilaria, Gillard Ben T, Shoemark Deborah K, Chandler Kyla, Achenbach Peter, Piemonti Lorenzo, Long Anna E, Gillespie Kathleen M, Lampasona Vito, Williams Alistair J K, BOX Study Group

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Autoantibodies to glutamate decarboxylase (GADA) are widely used in the prediction and classification of type 1 diabetes. GADA radiobinding assays (RBAs) using N-terminally truncated antigens offer improved specificity, but radioisotopes limit the high-throughput potential for population screening. Luciferase-based immunoprecipitation system (LIPS) assays are sensitive and specific alternatives to RBAs with the potential to improve risk stratification. The performance of assays using the Nanoluc luciferase (Nluc)-conjugated GAD65 constructs, Nluc-GAD65(96-585) and full length Nluc-GAD65(1-585), were evaluated in 434 well-characterized serum samples from patients with recent-onset type 1 diabetes and first-degree relatives. Nonradioactive, high-throughput LIPS assays are quicker and require less serum than RBAs. Of 171 relatives previously tested single autoantibody positive for autoantibodies to full-length GAD65 by RBA but had not progressed to diabetes, fewer retested positive by LIPS using either truncated (n = 72) or full-length (n = 111) antigen. The Nluc-GAD65(96-585) truncation demonstrated the highest specificity in LIPS assays overall, but in contrast to RBA, N-terminus truncations did not result in a significant increase in disease-specificity compared with the full-length antigen. This suggests that binding of nonspecific antibodies is affected by the conformational changes resulting from addition of the Nluc antigen. Nluc-GAD65(96-585) LIPS assays offer low-blood-volume, high-specificity GADA tests for screening and diagnostics.

Для цитирования: Wyatt Rebecca C, Grace Sian L, Brigatti Cristina, Marzinotto Ilaria, Gillard Ben T, Shoemark Deborah K, Chandler Kyla, Achenbach Peter, Piemonti Lorenzo, Long Anna E, Gillespie Kathleen M, Lampasona Vito, Williams Alistair J K, BOX Study Group. Improved Specificity of Glutamate Decarboxylase 65 Autoantibody Measurement Using Luciferase-Based Immunoprecipitation System Assays.. Diabetes. 2024. DOI: 10.2337/db23-0550.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.