m+Medelevator.RU
← Поиск публикаций
Gait & posture · 2025

Can we share data? - Kinematic consistency during walking in three different treadmill-based laboratories.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Van Bladel Anke, Senden Rachel, Meijer Kenneth, Meyns Pieter, Bar-On Lynn

Аннотация

BACKGROUND: Three-dimensional gait analysis is crucial for diagnosis and treatment planning. Treadmill-based laboratories efficiently collect 3D gait data over many consecutive steps. Pooling/sharing data across treadmill-based laboratories could enhance clinical utility. However, the inter-laboratory consistency of gait kinematics from treadmill-based systems is unknown.

RESEARCH QUESTION: How consistent are lower-limb kinematics of healthy subjects measured in three different treadmill-based gait laboratories?

METHODS: Eighteen volunteers (14 women; 27 ± 9 years; BMI 24 ± 3 kg/m2) walked in three treadmill-based laboratories (Motek Medical, The Netherlands) within one week. Per laboratory, participants completed 3-minute walking trials (0.9, 1.1, 1.3 m/s) wearing a non-weight-bearing harness and identical clothes and shoes. The same marker-set (Human-Body Model 2) and virtual reality configurations were used. Statistical Parametric Mapping was used to compare time-normalized kinematic curves of the lower-limb, averaged over 40 steps, between laboratories. Root mean square differences (RMSD) calculated over periods of the gait cycle with statistically significant differences were considered clinically meaningful when > 5°.

RESULTS AND SIGNIFICANCE: Kinematics curves from all laboratories followed similar patterns. Only 17 % of all curves displayed clinically relevant differences. These differences included more knee flexion in laboratory 2 compared to the others (RMSD 6.0-8.6°) and less hip flexion in laboratory 3 compared to laboratory 2 (all speeds) and to laboratory 1 (1.3 m/s; RMSD 5.4-6.4°). Reported differences are likely due to varying operator protocols rather than to the measurement system. The findings indicate that inter-laboratory data sharing using such infrastructure is possible but training to align protocols is essential.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты