Effect of cervical spine immobilization technique on pediatric advanced airway management: a high-fidelity infant simulation model.

Nishisaki Akira, Scrattish Louis, Boulet John, Kalsi Mandip, Maltese Matthew, Castner Thomas, Donoghue Aaron, Hales Roberta, Tyler Lisa, Brust Peter, Helfaer Mark, Nadkarni Vinay

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Current guidelines recommend cervical spine immobilization during orotracheal intubation when traumatic injury is suspected in infants. We evaluated the effect of cervical spine immobilization techniques on orotracheal intubation performance with a high-fidelity infant simulator.

METHODS

A randomized control study with repeated measurement. Nonanesthesia pediatric practitioners certified for intubation performed 6 intubations with 3 different cervical spine immobilization techniques (no physical protection, manual in-line immobilization, and cervical collar: C-collar). Time to accomplish key actions, cervical extension angle, and observed intubation associated events such as mainstem intubation, esophageal intubation with or without immediate recognition were recorded.

RESULTS

Twenty-six practitioners performed 156 successful orotracheal intubation. Time to intubation from end of mask assist ventilation was 29.0 +/- 12.2 seconds in no physical protection, 33.0 +/- 17.4 seconds in C-collar, and 33.0 +/- 17.1 seconds in manual in-line immobilization (P = 0.39). Maximal cervical extension angle in no physical protection (2.39 +/- 2.56 degrees ) and C-collar (2.65 +/- 1.79 degrees ) were significantly greater compared with 0.85 +/- 1.05 degrees in manual in-line immobilization (P < 0.0001). The number of intubation attempts and intubation associated events were not different among 3 techniques. Laryngeal visualization measured by Cormack-LehaneScale was more difficult in C-collar compared with other 2 techniques (P< 0.001).

CONCLUSIONS

In this high-fidelity infant simulator model, cervical spine immobilization technique affected cervical extension angle and laryngeal visualization. Tracheal intubation associated events occurred in 33% of intubation attempts but were not different by technique. Time to achieve tracheal intubation, number of intubation attempts needed to succeed, and intubation-associated events were not affected by immobilization techniques. These results support Advanced Trauma Life Support recommendations to perform manual in-line immobilization in infants.

Для цитирования: Nishisaki Akira, Scrattish Louis, Boulet John, Kalsi Mandip, Maltese Matthew, Castner Thomas, Donoghue Aaron, Hales Roberta, Tyler Lisa, Brust Peter, Helfaer Mark, Nadkarni Vinay. Effect of cervical spine immobilization technique on pediatric advanced airway management: a high-fidelity infant simulation model.. Pediatric emergency care. 2008. DOI: 10.1097/pec.0b013e31818c2665.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.