Predicting Breath Hold Task Compliance From Head Motion.

Weng Timothy B, Porwal Gargi, Srinivasan Dhivya, Inglis Ben, Rodriguez Sabrina, Jacobs David R, Schreiner Pamela J, Sorond Farzaneh A, Sidney Stephen, Lewis Cora, Launer Lenore, Erus Guray, Nasrallah Ilya M, Bryan R Nick, Dula Adrienne N

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cerebrovascular reactivity reflects changes in cerebral blood flow in response to an acute stimulus and is reflective of the brain's ability to match blood flow to demand. Functional MRI with a breath-hold task can be used to elicit this vasoactive response, but data validity hinges on subject compliance. Determining breath-hold compliance often requires external monitoring equipment.

PURPOSE: To develop a non-invasive and data-driven quality filter for breath-hold compliance using only measurements of head motion during imaging.

STUDY TYPE: Prospective cohort.

PARTICIPANTS

Longitudinal data from healthy middle-aged subjects enrolled in the Coronary Artery Risk Development in Young Adults Brain MRI Study, N = 1141, 47.1% female.

FIELD STRENGTH/SEQUENCE: 3.0 Tesla gradient-echo MRI.

ASSESSMENT: Manual labelling of respiratory belt monitored data was used to determine breath hold compliance during MRI scan. A model to estimate the probability of non-compliance with the breath hold task was developed using measures of head motion. The model's ability to identify scans in which the participant was not performing the breath hold were summarized using performance metrics including sensitivity, specificity, recall, and F1 score. The model was applied to additional unmarked data to assess effects on population measures of CVR.

STATISTICAL TESTS: Sensitivity analysis revealed exclusion of non-compliant scans using the developed model did not affect median cerebrovascular reactivity (Median [q1, q3] = 1.32 [0.96, 1.71]) compared to using manual review of respiratory belt data (1.33 [1.02, 1.74]) while reducing interquartile range.

RESULTS

The final model based on a multi-layer perceptron machine learning classifier estimated non-compliance with an accuracy of 76.9% and an F1 score of 69.5%, indicating a moderate balance between precision and recall for the identification of scans in which the participant was not compliant.

DATA

CONCLUSION

The developed model provides the probability of non-compliance with a breath-hold task, which could later be used as a quality filter or included in statistical analyses.

LEVEL OF EVIDENCE: 1: TECHNICAL EFFICACY: Stage 3.

Для цитирования: Weng Timothy B, Porwal Gargi, Srinivasan Dhivya, Inglis Ben, Rodriguez Sabrina, Jacobs David R, Schreiner Pamela J, Sorond Farzaneh A, Sidney Stephen, Lewis Cora, Launer Lenore, Erus Guray, Nasrallah Ilya M, Bryan R Nick, Dula Adrienne N. Predicting Breath Hold Task Compliance From Head Motion.. Journal of magnetic resonance imaging : JMRI. 2025. DOI: 10.1002/jmri.70105.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.