Аннотация
PURPOSE: To compare intraocular pressure (IOP) over time after standard trabeculectomy vs Ex-PRESS implantation in patients with bilateral primary open-angle glaucoma (POAG).
DESIGN
Prospective, randomised study.
PATIENTS AND
METHODS
This study included adult patients with bilateral POAG necessitating surgery. Each patient underwent trabeculectomy in one eye and Ex-PRESS implantation under a scleral flap in the other eye according to randomised contralateral allocations. Efficacy was assessed by IOP values and success rates (IOP threshold and/or need for topical glaucoma medication) during 30 months. Statistical analysis included Generalised Estimate Equation and Cox Survival models, and paired t-tests.
RESULTS
Thirty eyes of 15 patients were studied for a mean of 23.6 months (SD, ± 6.9). At the last follow-up visit, mean pre-operative IOP decreased from 31.1 (± 14.2) to 16.2 (± 1.5) mm Hg after trabeculectomy, and from 28.1 (± 9.0) to 15.7 (± 1.8) mm Hg after Ex-PRESS implantation (P=0.001). The mean number of anti-glaucoma medicines prescribed at the last follow-up decreased from 3.7 pre-operatively (both groups) to 0.9 after trabeculectomy vs 0.3 after Ex-PRESS implantation (P=0.001). Complete success rates (5<IOP<18 mm Hg without medications) were higher with Ex-PRESS compared with trabeculectomy (P=0.0024). Postoperative complications were more frequent after trabeculectomy (33%) compared with Ex-PRESS (20%), with four trabeculectomy eyes (27%) needing postoperative interventions, compared with none with Ex-PRESS.
CONCLUSIONS
Trabeculectomy and Ex-PRESS implantation provided similar IOP control, but the Ex-PRESS group had a lower rate of complications, fewer postoperative interventions, and needed less glaucoma medications.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.