Contact lens & anterior eye : the journal of the British Contact Lens Association · 2015
Higher spherical equivalent refractive errors is associated with slower axial elongation wearing orthokeratology.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Fu Ai-Cun, Chen Xing-Lin, Lv Yong, Wang Shu-Lin, Shang Li-Na, Li Xiu-Hong, Zhu Yu
Аннотация
PURPOSE: To investigate the relationship between axial length (AL) increase and baseline spherical equivalent refractive errors (SER) in myopic children wearing orthokeratology contact lenses (OK).
METHODS: One hundred fifteen Chinese (115 right eyes) children wearing OK were enrolled in this cohort study. Gender, age, baseline SER, corneal power, corneal astigmatism, and AL at baseline and 2 years after wearing OK were collected. Univariate analysis and trend test were used to estimate the relationship between change in AL and baseline SER.
RESULTS: After univariate analysis, a statistically significant relationship was found between change in AL and baseline SER (β=0.061, 95% CI: 0.015-0.111, P=0.015). In the trend test, after adjusting for potential confounders, higher SER was associated with smaller increases in AL (P trend=0.041).
CONCLUSIONS: The SER at baseline was associated with AL growth in myopic children wearing OK. The higher SER was associated with slower AL growth and control the development of myopia.
METHODS: One hundred fifteen Chinese (115 right eyes) children wearing OK were enrolled in this cohort study. Gender, age, baseline SER, corneal power, corneal astigmatism, and AL at baseline and 2 years after wearing OK were collected. Univariate analysis and trend test were used to estimate the relationship between change in AL and baseline SER.
RESULTS: After univariate analysis, a statistically significant relationship was found between change in AL and baseline SER (β=0.061, 95% CI: 0.015-0.111, P=0.015). In the trend test, after adjusting for potential confounders, higher SER was associated with smaller increases in AL (P trend=0.041).
CONCLUSIONS: The SER at baseline was associated with AL growth in myopic children wearing OK. The higher SER was associated with slower AL growth and control the development of myopia.