Rapid diagnosis and prognosis of malaria infection using a microfluidic point-of-care immunoassay.

Li Jiran, Saidi Alexuse M, Seydel Karl, Lillehoj Peter B

СтатьяПеревод пока не подготовлен

Аннотация

Malaria is a major cause of illness and death worldwide. Rapid diagnostic tests are the most widely used tool for detecting malaria infection, however, they only provide binary results and lack the sensitivity needed to detect many asymptomatic infections. Molecular assays for quantifying malaria biomarkers offer higher detection sensitivity, however, they are time-consuming, and require expert training and expensive equipment, making them unsuitable for use in most of Africa. To address the need for simple, accurate and field-deployable malaria diagnostic tests, we have developed a microfluidic point-of-care (mPOC) immunoassay for rapid quantification of Plasmodium falciparum histidine-rich protein 2 (PfHRP2), a malaria parasite biomarker, in whole blood. This device features two diagnostic modes for detecting PfHRP2 at low (100's pg/mL) and high (1,000's ng/mL) concentrations, making it useful for multiple diagnostic applications, including the detection of asymptomatic infection, prediction of disease outcomes and diagnosis of cerebral malaria. Measurements of PfHRP2 in blood samples from malaria patients demonstrates that this platform offers similar accuracy as an ultra-sensitive PfHRP2 enzyme-linked immunosorbent assay (ELISA) test, while being 12× faster and simpler to use. This mPOC immunoassay can be deployed in rural health centers to assist clinicians in diagnosing and triaging malaria patients, ultimately improving patient outcomes.

Для цитирования: Li Jiran, Saidi Alexuse M, Seydel Karl, Lillehoj Peter B. Rapid diagnosis and prognosis of malaria infection using a microfluidic point-of-care immunoassay.. Biosensors & bioelectronics. 2024. DOI: 10.1016/j.bios.2024.116091.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.