MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/tmi.12117

Медицинская библиотека · Tropical medicine & international health : TM & IH · 2013

Evaluation of urine-circulating cathodic antigen (Urine-CCA) cassette test for the detection of Schistosoma mansoni infection in areas of moderate prevalence in Ethiopia.

Erko Berhanu, Medhin Girmay, Teklehaymanot Tilahun, Degarege Abraham, Legesse Mengistu

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the diagnostic performance of antigen detecting urine-CCA cassette test for the detection of Schistosoma mansoni infection in areas of moderate prevalence in Ethiopia.

METHODS

Stool specimens were collected from 620 schoolchildren on three consecutive days. The samples were microscopically examined using double Kato slides; midstream urine specimens were also collected for three consecutive days and tested for S. mansoni. The sensitivity of the urine-CCA cassette test was determined using combined results of six Kato-Katz thick smears and three urine-CCA cassette tests as gold standard. The specificity of the urine-CCA cassette test was evaluated in an area where schistosomiasis is not endemic.

RESULTS

Prevalence of S. mansoni infection as determined by single urine-CCA cassette test was 65.9%, by single Kato-Katz smear 37.3% and by six Kato-Katz thick smears 53.1% (P < 0.001). A single urine-CCA cassette test was significantly (P < 0.001) more sensitive (89.1%), had a lower negative predictive value (78.2%), was more accurate (92.6%) and agreed better with the gold standard (k = 0.83) than one or six Kato-Katz thick smears. However, both the Kato-Katz and urine-CCA cassette test showed 100% specificity in endemic settings.

CONCLUSIONS

In moderate and high prevalence areas, urine-CCA cassette test is more sensitive than the Kato-Katz method and can be used for screening and mapping of S. mansoni infection.

Для цитирования: Erko Berhanu, Medhin Girmay, Teklehaymanot Tilahun, Degarege Abraham, Legesse Mengistu. Evaluation of urine-circulating cathodic antigen (Urine-CCA) cassette test for the detection of Schistosoma mansoni infection in areas of moderate prevalence in Ethiopia.. Tropical medicine & international health : TM & IH. 2013. DOI: 10.1111/tmi.12117.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.