MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.218.3.r01fe38783

Медицинская библиотека · Radiology · 2001

Comparison between MR imaging and 99mTc MIBI scintigraphy in the evaluation of recurrent of persistent hyperparathyroidism.

Gotway M B, Reddy G P, Webb W R, Morita E T, Clark O H, Higgins C B

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the sensitivity and positive predictive value of magnetic resonance (MR) imaging and technetium 99m 2-methoxyisobutyl-isonitrile (MIBI) scintigraphy for the detection of hyperfunctioning parathyroid tissue when used alone and in combination in a large patient population with recurrent or persistent hyperparathyroidism (HPT).

MATERIALS AND

METHODS

In 98 consecutive patients with biochemically proved recurrent or persistent HPT after surgery, MR imaging and 99mTc MIBI study findings were retrospectively reviewed and compared with surgical and histopathologic findings. The sensitivity and positive predictive value of MR imaging and 99mTc MIBI scintigraphy were compared with each other and in combination.

RESULTS

In these patients, 130 abnormal parathyroid glands were identified at surgery. The sensitivity and positive predictive value of MR imaging were 82% (95% CI: 75%, 89%) and 89%, respectively; those for (99m)Tc MIBI scintigraphy were 85% (95% CI: 79%, 91%) and 89%. No significant difference was found between MR imaging and 99mTc MIBI scintigraphy for sensitivity (P =.7). The sensitivity and positive predictive value for the detection of abnormal parathyroid tissue on a per-gland basis increased to 94% (95% CI: 90%, 98%) and 98%, respectively, when only one of the two tests was required to be positive.

CONCLUSION

MR imaging and 99mTc MIBI scintigraphy have similarly good sensitivity and positive predictive value for the detection of hyperfunctioning parathyroid tissue in patients after surgery. The combination of the two tests provided a substantial increase in sensitivity and positive predictive value.

Для цитирования: Gotway M B, Reddy G P, Webb W R, Morita E T, Clark O H, Higgins C B. Comparison between MR imaging and 99mTc MIBI scintigraphy in the evaluation of recurrent of persistent hyperparathyroidism.. Radiology. 2001. DOI: 10.1148/radiology.218.3.r01fe38783.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.