m+Medelevator.RU
← Поиск публикаций
Optometry and vision science : official publication of the American Academy of Optometry · 2014

Objectively determined refraction improves peripheral vision.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lewis Peter, Baskaran Karthikeyan, Rosén Robert, Lundström Linda, Unsbo Peter, Gustafsson Jörgen

Аннотация

PURPOSE: The purpose of this study was twofold: to verify a fast, clinically applicable method for determining off-axis refraction and to assess the impact of objectively obtained off-axis refractive correction on peripheral low-contrast visual acuity.

METHODS: We measured peripheral low-contrast resolution acuity with Gabor patches both with and without off-axis correction at 20 degrees in the nasal visual field of 10 emmetropic subjects; the correction was obtained using a commercial open-field Hartmann-Shack wavefront sensor, the COAS-HD VR aberrometer. Off-axis refractive errors were calculated for a 5-mm circular pupil inscribed within the elliptical wavefront by COAS using the instruments' inbuilt "Seidel sphere" method.

RESULTS: Most of the subjects had simple myopic astigmatism, at 20 degrees in the nasal visual field ranging from -1.00 to -2.00 DC, with axis orientations generally near 90 degrees. The mean uncorrected and corrected low-contrast resolution acuities for all subjects were 0.92 and 0.86 logMAR, respectively (an improvement of 0.06 logMAR). For subjects with a scalar power refractive error of 1.00 diopters or more, the average improvement was 0.1 logMAR. The observed changes in low-contrast resolution acuity were strongly correlated with off-axis astigmatism (Pearson r = 0.95; p < 0.0001), the J180 cross-cylinder component (Pearson r = 0.82; p = 0.0034), and power scalar (Pearson r = -0.75; p = 0.0126).

CONCLUSIONS: The results suggest that there are definite benefits in correcting even moderate amounts of off-axis refractive errors; in this study, as little as -1.50 DC of off-axis astigmatism gave improvements of up to a line in visual acuity. It may be even more pertinent for people who rely on optimal peripheral visual function, specifically those with central visual field loss; the use of open-field aberrometers could be clinically useful in rapidly determining off-axis refractive errors specifically for this patient group who are generally more challenging to refract.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты