m+Medelevator.RU
← Поиск публикаций
Journal of applied toxicology : JAT · 2006

Advantage of using CBA/N strain mice in a non-radioisotopic modification of the local lymph node assay.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Takeyoshi Masahiro, Noda Shuji, Yamasaki Kanji, Kimber Ian

Аннотация

The murine local lymph node assay (LLNA) is currently recognized as a stand-alone test method for determining the skin sensitizing potential of chemicals. It has been incorporated into the official test guidelines published by some authorities, including the OECD. To avoid the use of radioisotopes, efforts have been made recently to develop non-radioisotopic modifications of the LLNA. A non-radioisotopic modification of the LLNA was developed previously using 5-bromo-2'-deoxyuridine (BrdU) incorporation (non-RI LLNA). However, the non-RI LLNA was found to be somewhat less sensitive than the standard assay. This study reports the advantage of using mice of the CBA/N strain in the non-RI LLNA to improve the sensitivity of this method. The non-RI LLNA was performed using CBA/JN and CBA/N mice exposed to one of four confirmed skin sensitizers, 2,4-dinitrochlorobenzene (DNCB), eugenol (EG), isoeugenol (IEG) or alpha-hexylcinnamic aldehyde (HCA), and to one non-sensitizer, propylene glycol (PG). The EC3 values for DNCB, IEG, EG, HCA and PG were calculated to be 0.1%, 9.6%, 40.6%, 45.5% and >50% in CBA/JN mice and 0.08%, 1.9%, 10.7%, 20.3% and >50% in CBA/N mice, respectively. The EC3 values for DNCB, IEG, EG, HCA and PG in the standard LLNA using CBA/Ca mice and radioisotopes were reported elsewhere as being 0.08%, 1.3%, 13.0%, 8.0% and >50%, respectively. The EC3 values derived from the CBA/N mice in the non-RI LLNA were nearly equivalent to the EC3 values obtained using the standard radioisotopic LLNA with CBA/Ca mice. These data suggest that the use of CBA/N mice may provide a realistic opportunity to develop a version of the LLNA that does not have a requirement for the use of radioisotopes, but which nevertheless has sensitivity approaching, or comparable to, the standard method.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты