MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000000063

Медицинская библиотека · Nuclear medicine communications · 2014

Calibrated image-derived input functions for the determination of the metabolic uptake rate of glucose with [18F]-FDG PET.

Christensen Anders N, Reichkendler Michala H, Larsen Rasmus, Auerbach Pernille, Højgaard Liselotte, Nielsen Henning B, Ploug Thorkil, Stallknecht Bente, Holm Søren

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We investigated the use of a simple calibration method to remove bias in previously proposed approaches to image-derived input functions (IDIFs) when used to calculate the metabolic uptake rate of glucose (K(m)) from dynamic [(18)F]-FDG PET scans of the thigh. Our objective was to obtain nonbiased, low-variance K(m) values without blood sampling.

MATERIALS AND

METHODS

We evaluated eight previously proposed IDIF methods. K(m) values derived from these IDIFs were compared with Km values calculated from the arterial blood samples (gold standard). We used linear regression to extract calibration parameters to remove bias. Following calibration, cross-validation and bootstrapping were used to estimate the mean square error and variance.

RESULTS

Three of the previously proposed methods failed mainly because of zero-crossings of the IDIF. The remaining five methods were improved by calibration, yielding unbiased Km values. The method with the lowest SD yielded an SD of 0.0017/min--that is, below 10% of the muscle K(m) value in this study.

CONCLUSION

Previously proposed IDIF methods can be improved by using a simple calibration procedure. The calibration procedure may be used in other studies, thus obviating the need for arterial blood sampling, once the calibration parameters have been established in a subgroup of participants. The method has potential for use in other parts of the body as it is robust with regard to partial volume effects.

Для цитирования: Christensen Anders N, Reichkendler Michala H, Larsen Rasmus, Auerbach Pernille, Højgaard Liselotte, Nielsen Henning B, Ploug Thorkil, Stallknecht Bente, Holm Søren. Calibrated image-derived input functions for the determination of the metabolic uptake rate of glucose with [18F]-FDG PET.. Nuclear medicine communications. 2014. DOI: 10.1097/mnm.0000000000000063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.