DOI 10.1016/j.jacep.2019.06.003
Sex-Related Procedural Aspects and Complications in CRT Survey II: A Multicenter European Experience in 11,088 Patients.
Аннотация
OBJECTIVES
This study sought to compare sex difference for procedural aspects and complications in the European Society of Cardiology CRT Survey II, exploring whether adverse events were related to the type of CRT device implanted.
BACKGROUND
Sex-related differences in procedural aspects and complications in patients undergoing cardiac resynchronization therapy (CRT) implantation has not been explored in a real-life population.
METHODS
A post-hoc analysis of procedural data and complications in different sexes and factors associated with events was performed from data collected in the European Society of Cardiology CRT Survey II.
RESULTS
Of all patients (n = 11,088) included, 24.3% were women. The mean age (70 years of age) of male and female recipients was similar. Female patients more frequently had an idiopathic cardiomyopathy (67.4% vs. 44.1%) and fewer comorbidities, including atrial fibrillation (34.8% vs. 42.8%), diabetes (29.1% vs. 32.1%), chronic obstructive lung disease (10.3% vs. 12.6%), and renal failure (28.7% vs. 31.9%), compared with men. More women compared with men had a pacemaker (56.6% vs. 46.3%) and much less often an implantable cardioverter-defibrillator (CRT-D) (19.0% vs. 34.7%) implant. Periprocedural event rate was the highest in women with CRT with defibrillator (7.1% vs. 4.8% in men), followed by women with a CRT with pacing (5.5% vs. 4.4% in men). The higher periprocedural event rate in CRT-D women was attributable primarily to the occurrence of pneumothorax (1.4%), coronary sinus dissection (2.1%), and pericardial tamponade (0.3%). The rate of in-hospital major adverse events (6.0%) and complications necessitating reoperation (4.0%) was not different among sex and device type.
CONCLUSIONS
Women are more likely to experience adverse procedure-related events during CRT implantation. Thus, preventive strategies should be employed to minimize complication rate.