MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2011.03.041

Медицинская библиотека · Journal of cataract and refractive surgery · 2011

Flattening of the cornea after collagen crosslinking for keratoconus.

Koller Tobias, Pajic Bojan, Vinciguerra Paolo, Seiler Theo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To identify preoperative parameters that may predict flattening of the keratoconic cornea after collagen crosslinking (CXL).

SETTING

Institut für Refraktive und Ophthalmo-Chirurgie (IROC), Zurich, Switzerland.

DESIGN

Cohort study.

METHODS

Patients with verified progressive primary keratectasia received standard corneal CXL. Factors such as corrected distance visual acuity (CDVA) and Scheimpflug tomography (Pentacam) were used to follow the evolution from preoperatively to 12 months after CXL. Statistical analysis included U tests and Spearman rank correlation tests to detect risk factors for flattening of the keratoconus.

RESULTS

The study enrolled 151 eyes of 151 patients; more than 80% completed the 12-month follow-up. The flattening rate (flattening of the maximum curvature >1.00 diopter [D]) was 37.7%. A preoperative maximum keratometry (K) reading of more than 54.00 D was identified as the only significant risk factor for this effect (odds ratio, 1.88; 95% confidence interval, 1.01-3.51). A restriction to corneas with a maximum K value greater than 54.00 D would have resulted in a significant flattening in 51% of the cases.

CONCLUSIONS

Statistically significant flattening occurred during 1 year after CXL in more than 50% of cases when the preoperative maximum K reading was more than 54.00 D. None of the other preoperative parameters evaluated (eg, age, sex, diagnosis, CDVA, corneal shape factors) had a statistically significant impact on corneal flattening after CXL.

Для цитирования: Koller Tobias, Pajic Bojan, Vinciguerra Paolo, Seiler Theo. Flattening of the cornea after collagen crosslinking for keratoconus.. Journal of cataract and refractive surgery. 2011. DOI: 10.1016/j.jcrs.2011.03.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.