Nuklearmedizin. Nuclear medicine · 2014

Real-time ultrasound and freehand-SPECT. Experiences with sentinel lymph node mapping.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Freesmeyer M, Winkens T, Opfermann T, Elsner P, Runnebaum I, Darr A

Аннотация

UNLABELLED: Aim of this work is to report first experiences of the feasibility and applicability of a hybrid freehandSPECT/ultrasound (fh-SPECT/US) imaging concept, with regard to SLN imaging, in patients with breast cancer and malignant melanoma.

PATIENTS, METHODS: 18 patients with breast cancer or malignant melanoma received standard SLN scintigraphy. Following this, fh-SPECT using declipse®SPECT (SurgicEye, Munich, Germany) was performed, a handheld-gamma camera-based method to visualize activity distribution within a region of interest as a cross-sectional data set. These data were transferred to an ultrasound device and sensor-navigated ultrasound was performed combining fh-SPECT data with ultrasound images, displaying superimposed images. Quality of fh-SPECT and co-registration accuracy was assigned to one of four categories and occurrence of artefacts was assessed.

RESULTS: In 4/18 examinations, there was a no deviation regarding co-registration of both data sets. For 9/18 patients, there was a deviation of <1 cm (mean 0.7±0.3 cm, range 0.3-1.0 cm). For 3/18 patients, a deviation >1 cm was present (mean 1.7±0.3 cm, range 1.5-2.0 cm). In 2/18 examinations no lymph node was found in the region of highest activity. Fh-SPECT reconstruction artifacts occurred in 6/18 examinations.

CONCLUSION: The fusion imaging concept combining SLN information with ultrasound images presented here proves to be feasible and technically successful. However, significant technical limitations were shown in fh-SPECT quality and fusion precision. Subject to technical optimisation of SPECT quality and co-registration, a meaningful contribution to the preoperative planning of lymph node therapy is imaginable. Thus, fundamentally a preoperative histological examination by fh-SPECT/US-guided biopsy is possible.