Complex cardiac implantable electronic device infections in Alberta, Canada: An epidemiologic cohort study of validated administrative data.
Аннотация
OBJECTIVE
To establish the epidemiology of cardiac implantable electronic device (CIED) infections in Alberta, Canada, using validated administrative data.
DESIGN
Retrospective, population-based cohort study.
SETTING
Alberta Health Services is a province-wide health system that services all of Alberta, Canada.
PARTICIPANTS
Adult patients who underwent first-time CIED implantation or generator replacement in Alberta, Canada, between January 1, 2011, and December 31, 2019.
METHODS
CIED implant patients were identified from the Paceart database. Patients who developed an infection within 1 year of the index procedure were identified through validated administrative data (International Classification of Diseases, Tenth Revision in Canada). Demographic characteristics of patients were summarized. Logistic regression models were used to analyze device type, comorbidities, and demographics associated with infection rates and mortality.
RESULTS
Among 27,830 CIED implants, there were 205 infections (0.74%). Having 2 or more comorbidities was associated with higher infection risk. Generator replacement procedures (odds ratio [OR], 0.55; 95% confidence interval [CI], 0.34-0.84; P = .008), age increase of every 10 years (OR, 0.73; 95% CI, 0.66-0.82; P ≤ .001), and index procedure after 2014 were associated with decreased risk. Comparing the infected to uninfected groups, the hospitalization rates were 2.63 compared to 0.69, and the mortality rates were 10.73% compared to 3.49%, respectively (P < .001).
CONCLUSIONS
There is a slightly lower overall rate of CIED infections Alberta, Canada compared to previously described epidemiology. Implants after 2014, and generator replacements showed a decreased burden of infection. Patients with younger age, and 2 or more comorbidities are at greatest risk of CIED infection. The burden of hospitalization and mortality is substantially higher in infected patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.