MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2013.08.055

Медицинская библиотека · Journal of cataract and refractive surgery · 2014

Opaque bubble layer: incidence, risk factors, and clinical relevance.

Liu Chun-Hsiu, Sun Chi-Chin, Hui-Kang Ma David, Chien-Chieh Huang Jerry, Liu Chun-Fu, Chen Hsi-Fu, Hsiao Ching-Hsi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the incidence, risk factors, and impact on visual outcomes of an opaque bubble layer (OBL) produced by an Intralase femtosecond laser (60 kHz) during laser in situ keratomileusis (LASIK).

SETTING

Laser Vision Center, Chang Gung Memorial Hospital, Keelung, Taiwan.

DESIGN

Case series.

METHODS

Patients had femtosecond laser-assisted LASIK surgery. The surgical procedures were videotaped, and the patterns and sizes of the OBLs noted during the operations were analyzed. Preoperative and postoperative data included patient demographics, visual acuity, contrast sensitivity, refractive status, keratometry, and intraoperative data (eg, flap size, flap thickness, and docking times).

RESULTS

The study analyzed 23 patients (40 eyes). Twenty-one eyes (52.5%) developed an OBL, 40.0% with a hard pattern and 12.5% with a soft pattern. The hard OBLs covered a mean area of 28.6% ± 10.1% (SD) and the soft OBLs, of 7.4% ± 5.6% (P = .002). The preoperative central cornea was significantly thicker in eyes that developed an OBL (P = .045). The visual outcomes 1 month postoperatively were comparable between the 2 groups except that eyes with an OBL had slightly decreased contrast sensitivity under scotopic conditions.

CONCLUSIONS

Thicker corneas tended to develop an OBL during femtosecond laser-assisted LASIK surgery. An OBL did not affect postoperative visual acuity except for a mild decrease in scotopic contrast sensitivity.

Для цитирования: Liu Chun-Hsiu, Sun Chi-Chin, Hui-Kang Ma David, Chien-Chieh Huang Jerry, Liu Chun-Fu, Chen Hsi-Fu, Hsiao Ching-Hsi. Opaque bubble layer: incidence, risk factors, and clinical relevance.. Journal of cataract and refractive surgery. 2014. DOI: 10.1016/j.jcrs.2013.08.055.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.