MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejmp.2026.105717

Медицинская библиотека · Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026

Utility of respiratory motion correction and effects on dosimetry in imaging with integrated Y-90 PET/MRI after radioembolization of liver tumors.

Demir Burak, Soydal Cigdem, Mesci Irem, Celebioglu Emre Can, Bilgic Mehmet Sadik, Kuru Oz Digdem, Kucuk Nuriye Ozlem

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: In this study we aimed to investigate the utility of respiratory motion correction using the Q.Static algorithm in integrated Y-90 PET/MR imaging and its impact on dosimetric accuracy, image quality, and dose-volume histograms following radioembolization of the liver tumors.

METHODS

This retrospective single-center analysis included 23 patients treated with Y-90 resin microspheres and imaged with Y-90 PET/MRI. Respiratory motion-corrected (Q.Static) and standard non-corrected PET reconstructions were compared for dosimetric variables, image quality (signal-to-noise ratio, SNR), and activity quantification. Tumor dose-volume histograms (D1-D99) and absorbed doses were calculated with absolute quantification and local dose deposition method. Bland-Altman plots and regression analyses were employed to assess differences between the two methods and investigate correlations with tumor volume.

RESULTS

Q.Static sequences resulted in 7.08 % (95 % CI: [+4.82 %] - [+9.34 %]) higher tumor, 9.38 % (95 % CI: [+7.55 %] - [+10.67 %]) higher normal tissue absorbed doses compared to standard reconstructions, resulting in similar T/N ratios. In addition, Q.Static images demonstrated significantly higher D1, D5, and D10 values but lower D90 and D95 values. SNR was 33.62 % lower, and extrahepatic activity was 46.65 % higher in Q.Static sequences, reflecting noise-related degradation. Tumor volume significantly influenced dose variability, with smaller lesions showing greater differences between methods.

CONCLUSION

Respiratory motion correction in Y-90 PET/MRI may improve contrast and dose quantification in smaller lesions but may reduce image quality in low-activity cases due to noise. While promising for accurate dosimetry, its impact on clinical outcomes and response prediction warrants further studies.

Для цитирования: Demir Burak, Soydal Cigdem, Mesci Irem, Celebioglu Emre Can, Bilgic Mehmet Sadik, Kuru Oz Digdem, Kucuk Nuriye Ozlem. Utility of respiratory motion correction and effects on dosimetry in imaging with integrated Y-90 PET/MRI after radioembolization of liver tumors.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2026. DOI: 10.1016/j.ejmp.2026.105717.