Evaluation of a flow cytometric test for G6PD-deficient erythrocytes.

Kapadia Alpeshkumar Bipinbhai, Sharma Prashant, Jain Karuna, Sachdeva Man Updesh Singh, Bose Parveen Lata, Gupta Minakshi, Khadwal Alka Rani, Bal Amanjit, Das Reena, Varma Neelam

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Glucose-6-phosphate dehydrogenase (G6PD) deficiency, an X-linked recessive disorder, is the commonest erythrocytic enzymopathy worldwide. Reliable diagnosis and severity prediction in G6PD-deficient/heterozygous females remain challenging. A recently developed flow cytometric test for G6PD deficiency has shown promise in precisely identifying deficient females. This paper presents our experiences with this test in a subtropical setting and presents a modification in flow cytometric data acquisition strategy.

METHODS

The methaemoglobin reduction + ferryl Hb generation-based flow cytometric G6PD test was compared with the screening methaemoglobin reduction test (MRT) and confirmatory G6PD enzyme activity assay (EAA) in 20 G6PD-deficient males, 22 G6PD-heterozygous/deficient females and 20 controls. Stained cells were also assessed for bright/dim G6PD activity under a fluorescent microscope.

RESULTS

Flow cytometry separated and quantified %bright cells in heterozygous/deficient females, objectively classifying them into 6 normal (>85% bright cells), 14 intermediate (10-85%) and two G6PD-deficient (<10% bright cells). Concordance with MRT was 89% (55/62 cases) and with EAA was 77% (48/62 cases). Fluorometrically predicted violet laser excitation (405-nm) with signal acquisition in the 425-475 nm region was a technical advancement noted for the first time in this paper.

CONCLUSION

Flow cytometry/fluorescence microscopy represent technically straightforward methods for the detection and quantification of G6PD-deficient erythrocytes. Based on our results, we recommend their application as a first-line investigation to screen females who are prescribed an oxidant drug like primaquine or dapsone.

Для цитирования: Kapadia Alpeshkumar Bipinbhai, Sharma Prashant, Jain Karuna, Sachdeva Man Updesh Singh, Bose Parveen Lata, Gupta Minakshi, Khadwal Alka Rani, Bal Amanjit, Das Reena, Varma Neelam. Evaluation of a flow cytometric test for G6PD-deficient erythrocytes.. Tropical medicine & international health : TM & IH. 2021. DOI: 10.1111/tmi.13547.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.