Comparing bedside methods of determining placement of gastric tubes in children.

Ellett Marsha L Cirgin, Cohen Mervyn D, Croffie Joseph M B, Lane Kathleen A, Austin Joan K, Perkins Susan M

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to compare the accuracy and predictive validity of pH, bilirubin, and CO2 in identifying gastric tube placement errors in children.

DESIGN AND

METHODS

After the tube was inserted into 276 children, the CO2 monitor reading was obtained. Fluid was then aspirated to test pH and bilirubin.

RESULTS

Lack of ability to obtain tube aspirate was the best predictor of NG/OG placement errors with a sensitivity of 34.9% and a positive predictive value of 66.7%. Measuring pH, bilirubin, and CO2 of tube aspirate was less helpful.

PRACTICE IMPLICATIONS: Healthcare providers should suspect NG/OG tube misplacement when no fluid is aspirated.

Для цитирования: Ellett Marsha L Cirgin, Cohen Mervyn D, Croffie Joseph M B, Lane Kathleen A, Austin Joan K, Perkins Susan M. Comparing bedside methods of determining placement of gastric tubes in children.. Journal for specialists in pediatric nursing : JSPN. 2013. DOI: 10.1111/jspn.12054.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.