Cardiology in the young · 2014
Reducing patient radiation exposure during paediatric SVT ablations: use of CARTO® 3 in concert with "ALARA" principles profoundly lowers total dose.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pass Robert H, Gates Gregory G, Gellis Laura A, Nappo Lynn, Ceresnak Scott R
Аннотация
BACKGROUND: "ALARA--As Low As Reasonably Achievable" protocols reduce patient radiation dose. Addition of electroanatomical mapping may further reduce dose.
METHODS: From 6/11 to 4/12, a novel ALARA protocol was utilised for all patients undergoing supraventricular tachycardia ablation, including low frame rates (2-3 frames/second), low fluoro dose/frame (6-18 nGy/frame), and other techniques to reduce fluoroscopy (ALARA). From 6/12 to 3/13, use of CARTO® 3 (C3) with "fast anatomical mapping" (ALARA+C3) was added to the ALARA protocol. Intravascular echo was not utilised. Demographics, procedural, and radiation data were analysed and compared between the two protocols.
RESULTS: A total of 75 patients were included: 42 ALARA patients, and 33 ALARA+C3 patients. Patient demographics were similar between the two groups. The acute success rate in ALARA was 95%, and 100% in ALARA+C3; no catheterisation-related complications were observed. Procedural time was 125.7 minutes in the ALARA group versus 131.4 in ALARA+C3 (p=0.36). Radiation doses were significantly lower in the ALARA+C3 group with a mean air Kerma in ALARA+C3 of 13.1±28.3 mGy (SD) compared with 93.8±112 mGy in ALARA (p<0.001). Mean dose area product was 92.2±179 uGym2 in ALARA+C3 compared with 584±687 uGym2 in ALARA (p<0.001). Of the 33 subjects (42%) in the ALARA+C3 group, 14 received ⩽1 mGy exposure. The ALARA+C3 dosages are the lowest reported for a combined electroanatomical-fluoroscopy technique.
CONCLUSIONS: Addition of CARTO® 3 to ALARA protocols markedly reduced radiation exposure to young people undergoing supraventricular tachycardia ablation while allowing for equivalent procedural efficacy and safety.
METHODS: From 6/11 to 4/12, a novel ALARA protocol was utilised for all patients undergoing supraventricular tachycardia ablation, including low frame rates (2-3 frames/second), low fluoro dose/frame (6-18 nGy/frame), and other techniques to reduce fluoroscopy (ALARA). From 6/12 to 3/13, use of CARTO® 3 (C3) with "fast anatomical mapping" (ALARA+C3) was added to the ALARA protocol. Intravascular echo was not utilised. Demographics, procedural, and radiation data were analysed and compared between the two protocols.
RESULTS: A total of 75 patients were included: 42 ALARA patients, and 33 ALARA+C3 patients. Patient demographics were similar between the two groups. The acute success rate in ALARA was 95%, and 100% in ALARA+C3; no catheterisation-related complications were observed. Procedural time was 125.7 minutes in the ALARA group versus 131.4 in ALARA+C3 (p=0.36). Radiation doses were significantly lower in the ALARA+C3 group with a mean air Kerma in ALARA+C3 of 13.1±28.3 mGy (SD) compared with 93.8±112 mGy in ALARA (p<0.001). Mean dose area product was 92.2±179 uGym2 in ALARA+C3 compared with 584±687 uGym2 in ALARA (p<0.001). Of the 33 subjects (42%) in the ALARA+C3 group, 14 received ⩽1 mGy exposure. The ALARA+C3 dosages are the lowest reported for a combined electroanatomical-fluoroscopy technique.
CONCLUSIONS: Addition of CARTO® 3 to ALARA protocols markedly reduced radiation exposure to young people undergoing supraventricular tachycardia ablation while allowing for equivalent procedural efficacy and safety.